FUKUDA Makoto

Department of Biomedical EngineeringProfessor

Last Updated :2024/08/31

■Researcher basic information

Research Keyword

  • 医用化学工学   医用生体工学   人工臓器   血液浄化   

Research Field

  • Manufacturing technology (mechanical, electrical/electronic, chemical engineering) / Applied biofunctional and bioprocess engineering / biomedical engineering; clinical engineer; membrane science artificial organs; artificial kidney (dialyzer); extracorporeal membrane oxygenation (ECMO); fouling; biocompatibility

■Career

Career

  • 2014/04 - Today  Kindai UniversityFaculty of Biology-Oriented Science and Technology, Department of Biomedical Engineering
  • 2006/04  Himeji Dokkyo UniversityFaculty of Health Care Sciences Department of Medical Engineering
  • 1993/04  旭化成(株)Asahi Kasei Corporation、旭化成メディカル(株)Asahi Kasei Medical

Educational Background

  •        - 1993/03  Waseda University  Graduate School of Science and Engineering  応用化学専攻

■Research activity information

Award

  • 2018/06 日本生体医工学会 論文賞・阪本賞
     
    受賞者: 福田 誠;滑川亘希;酒井清孝
  • 2016/11 公益社団法人_発明協会 九州地方発明表彰_発明奨励賞
     
    受賞者: 福田 誠;内幸彦;上住敏士;日高秀敏;藤村崇保
  • 2009 the Japanese Society of Artificial Organs (JSAO), the society's article awards
     
    受賞者: Masato Matsuda;Mika Sato;Hiroki Sakata;Takahisa Ogawa;Ken-ichiro Yamamoto;Taiji yakushiji;Makoto Fukuda;Takehiro MIyasaka;Kiyotaka Sakai
  • 2004 日本人工臓器学会技術賞
     内部濾過促進型ダイアライザ JPN 
    受賞者: 福田誠;宮崎美和;上住敏士;日吉辰夫;藤村崇保;内幸彦
  • 2001 日本人工臓器学会論文賞
     JPN 
    受賞者: 福田誠;日吉辰夫;酒井清孝;小久保謙一
  • 1995 日本人工臓器学会論文賞
     JPN 
    受賞者: 金森敏幸;酒井清孝;福田誠

Paper

  • Makoto Fukuda; Kazunori Sadano; Tomoki Maeda; Eri Murata; Naoyuki Miyashita; Tsutomu Tanaka; Tomohiro Mori; Akane Saito; Kiyotaka Sakai
    Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 2024/08 [Refereed]
     
    Since the COVID-19 pandemic of 2020-2023, extracorporeal membrane oxygenator (ECMO) has attracted considerable attention worldwide. It is expected that ECMO with long-term durability is put into practical use in order to prepare for next emerging infectious diseases and to facilitate manufacturing for novel medical devices. Polypropylene (PP) and polymethylpentene (PMP) capillary membranes are currently the mainstream for gas exchange membrane for ECMO. ECMO support days for COVID-19-related acute hypoxemic respiratory failure have been reported to be on average for 14 or 24 days. It is necessary to improve opposing functions such that promoting the permeation of oxygen and carbon dioxide and inhibiting the permeation of water vapor or plasma to develop sufficient durability for long-term use. For this purpose, accurately controlling the anisotropy of the pore structure of the entire cross section and functions of capillary membrane is significant. In this study, we focused on the cross-sectional ion-milling (CSIM) method, to precisely clarify the pore structure of the entire cross section of capillary membrane for ECMO, because there is less physical stress on the porous structure applied during the preparation of cross-sectional samples of porous capillary membranes. We attempted to observe the cross sections of commercially available PMP membranes using the CSIM method. As a result, we succeeded in fabricating fine-scale flat cross-sectional samples of PMP capillary membranes. The pore structures and the degree of anisotropy of the cross sections are quantitatively clarified. The achievements and the approaches of this study are being applied to the development of next-generation gas exchange membranes.
  • Makoto Fukuda; Kiyotaka Sakai
    Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 2024/02 [Refereed][Invited]
     
    The evolution of hemodialysis membranes (dialyzer, artificial kidney) was remarkable, since Dow Chemical began manufacturing hollow fiber hemodialyzers in 1968, especially because it involved industrial chemistry, including polymer synthesis and membrane manufacturing process. The development of hemodialysis membranes has brought about the field of medical devices as a major industry. In addition to conventional electron microscopy, scanning probe microscopy (SPM), represented by atomic force microscopy (AFM), has been used in membrane science research on porous membranes for hemodialysis, and membrane science contributes greatly to the hemodialyzer industry. Practical studies of membrane porous structure-function relationship have evolved, and methods for analyzing membrane cross-sectional morphology were developed, such as the ion milling method, which was capable of cutting membrane cross sections on the order of molecular size to obtain smooth surface structures. Recently, following the global pandemic of SARS-CoV-2 infection, many studies on new membranes for extracorporeal membrane oxygenator have been promptly reported, which also utilize membrane science researches. Membrane science is playing a prominent role in membrane-based technologies such as separation and fabrication, for hemodialysis, membrane oxygenator, lithium ion battery separators, lithium recycling, and seawater desalination. These practical studies contribute to the global medical devices industry.
  • 走査型プローブ顕微鏡(SPM)による血液濾過膜のファウリング前後の膜内表面構造解析
    福田 誠; 定野 和憲; 佐々木 悠偉; 大森 結友; 竿本 仁志; 森 智博; 酒井 清孝
    腎と透析 (株)東京医学社 96 (別冊 ハイパフォーマンスメンブレン'23) 52 - 65 0385-2156 2024/01
  • Makoto Fukuda
    Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 1 - 6 2023/03 [Refereed]
     
    Hollow fiber membrane is incorporated into an extracorporeal membrane oxygenator (ECMO), and the function of the membrane determines the ECMO's functions, such as gas transfer rate, biocompatibility, and durability. In Japan, the membrane oxygenator to assist circulation and ventilation is approved for ECMO support. However, in all cases, the maximum use period has been only 6 h, and so-called 'off-label use' is common for ECMO support of severely ill COVID-19 patients. Under these circumstances, the HLS SET Advanced (Getinge Group Japan K.K.) was approved in 2020 for the first time in Japan as a membrane oxygenator with a two-week period of use. Following this membrane oxygenator, it is necessary to establish a domestic ECMO system that is approved for long-term use and suitable for supporting patients. Looking back on the evolution of ECMO so far, Japanese researchers and manufacturers have also contributed to the developments of ECMO globally. Currently, excellent membrane oxygenators and systems have been marketed by Japanese manufacturers and some of them are globally acclaimed, but in fact, most of the ECMO membranes are not made in Japan. Fortunately, Japan has led the world in the fields of membrane separation technology and hollow fiber membrane production. In the wake of this pandemic, from the perspective of medical and economic security, the practical use of purely domestic hollow fiber membranes and membrane oxygenators for long-term ECMO is imperative in anticipation of the next pandemic.
  • Makoto Fukuda; Ryo Tanaka; Kazunori Sadano; Asako Tokumine; Tomohiro Mori; Hitoshi Saomoto; Kiyotaka Sakai
    Membranes 12 (3) 2022/03 [Refereed]
     
    When using the extracorporeal capillary membrane oxygenator (sample A) for ECMO treatments of COVID-19 severely ill patients, which is dominantly used in Japan and worldwide, there is a concern about the risk of SARS-CoV-2 scattering from the gas outlet port of the membrane oxygenator. Terumo has launched two types of membranes (sample A and sample B), both of which are produced by the microphase separation processes using polymethylpentene (PMP) and polypropylene (PP), respectively. However, the pore structures of these membranes and the SARS-CoV-2 permeability through the membrane wall have not been clarified. In this study, we analyzed the pore structures of these gas exchange membranes using our previous approach and verified the SARS-CoV-2 permeation through the membrane wall. Both have the unique gradient and anisotropic pore structure which gradually become denser from the inside to the outside of the membrane wall, and the inner and outer surfaces of the membrane have completely different pore structures. The pore structure of sample A is also completely different from the other membrane made by the melt-extruded stretch process. From this, the pore structure of the ECMO membrane is controlled by designing various membrane-forming processes using the appropriate materials. In sample A, water vapor permeates through the coating layer on the outer surface, but no pores that allow SARS-CoV-2 to penetrate are observed. Therefore, it is unlikely that SARS-CoV-2 permeates through the membrane wall and scatter from sample A, raising the possibility of secondary ECMO infection. These results provide new insights into the evolution of a next-generation ECMO membrane.
  • 福田誠
    分離技術 51 (6) 1343-7860 2021/11
  • Makoto Fukuda; Tomoya Furuya; Kazunori Sadano; Asako Tokumine; Tomohiro Mori; Hitoshi Saomoto; Kiyotaka Sakai
    Membranes 11 (7) 2021/07 [Refereed]
     
    The objective of this study is to clarify the pore structure of ECMO membranes by using our approach and theoretically validate the risk of SARS-CoV-2 permeation. There has not been any direct evidence for SARS-CoV-2 leakage through the membrane in ECMO support for critically ill COVID-19 patients. The precise pore structure of recent membranes was elucidated by direct microscopic observation for the first time. The three types of membranes, polypropylene, polypropylene coated with thin silicone layer, and polymethylpentene (PMP), have unique pore structures, and the pore structures on the inner and outer surfaces of the membranes are completely different anisotropic structures. From these data, the partition coefficients and intramembrane diffusion coefficients of SARS-CoV-2 were quantified using the membrane transport model. Therefore, SARS-CoV-2 may permeate the membrane wall with the plasma filtration flow or wet lung. The risk of SARS-CoV-2 permeation is completely different due to each anisotropic pore structure. We theoretically demonstrate that SARS-CoV-2 is highly likely to permeate the membrane transporting from the patient's blood to the gas side, and may diffuse from the gas side outlet port of ECMO leading to the extra-circulatory spread of the SARS-CoV-2 (ECMO infection). Development of a new generation of nanoscale membrane confirmation is proposed for next-generation extracorporeal membrane oxygenator and system with long-term durability is envisaged.
  • Makoto Fukuda; Asako Tokumine; Kyohei Noda; Kiyotaka Sakai
    Membranes 10 (11) 2020/11 [Refereed]
     
    This article developes a pediatric membrane oxygenator that is compact, high performance, and highly safe. This novel experimental approach, which imaging the inside of a membrane oxygenator during fluid perfusion using high-power X-ray CT, identifies air and blood retention in the local part of a membrane oxygenator. The cause of excessive pressure drop in a membrane oxygenator, which has been the most serious dysfunction in cardiovascular surgery and extracorporeal membrane oxygenation (ECMO), is the local retention of blood and air inside the oxygenator. Our designed blood flow channel for a membrane oxygenator has a circular channel and minimizes the boundary between laminated parts. The pressure drop in the blood flow channel is reduced, and the maximum gas transfer rates are increased by using this pediatric membrane oxygenator, as compared with the conventional oxygenator. Furthermore, it would be possible to reduce the incidents, which have occurred clinically, due to excessive pressure drop in the blood flow channel of the membrane oxygenator. The membrane oxygenator is said to be the "last stronghold" for patients with COVID-19 receiving ECMO treatment. Accordingly, the specification of our prototype is promising for low weight and pediatric patients.
  • Makoto Fukuda; Hitoshi Saomoto; Tomohiro Mori; Hiroki Yoshimoto; Rei Kusumi; Kiyotaka Sakai
    Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs 23 (2) 171 - 179 1434-7229 2020/06 [Refereed]
     
    We examined typical commercial poly(ethersulfone) (PESf) hemodialysis and hemoconcentration membranes successfully used in manufacturing, and employed scanning probe microscope (SPM) to achieve a structural observation of the pores in the inner membrane surfaces, as well as measure the pore diameters and their distribution, verifying the relationship between the typical mass transfer properties. We focused on the differences between the PESf membranes which were expected to further improve the advanced pore structure control and functional design for various medical uses. The three-dimensional tortuous capillary pores on the inner surface of hollow fiber hemodialysis and hemoconcentrator membranes were investigated using dynamic force microscopy (DFM), and the pore diameter and distribution were measured through a line analysis. Compared with PUREMA-A, PES-Sα hemodialysis membranes have smaller three-dimensional tortuous capillary pore diameters and pore areas, as well as a smaller pore diameter distribution and pore area distribution, which make the accurate measurements of the pore diameter using FE-SEM impossible. These PESf membranes are almost the same in pure water permeability, but greatly differ in pore diameter and pore diameter distribution. By comparing and verifying as above, we may gain insight into the flexibility, versatility, and superior structural and functional controllability of PESf membrane pore structures, which could advance the development of pore structure control. Pending issues include the fact that, using a line analysis software of SPM devices, it is very difficult to measure hundred pores which clearly reflects the poor quality of pore size distributions obtained in this study, measurement accuracy must be improved further.
  • 膜工学(血液浄化膜)における最近の進歩と今後への期待
    福田 誠
    日本透析医会雑誌 (公社)日本透析医会 35 (1) 126 - 134 0914-7136 2020/04 [Refereed]
     
    Thomas Grahamが拡散の原理を1854年に発見し、Dow Chemical社が1968年に中空糸型血液浄化器の量産を始めてから、血液浄化技術は大きな進化を遂げた。その中でも血液浄化膜の進歩には特筆すべきものがあり、特に高分子の合成と中空糸膜の製膜技術などの工業化学を巻き込んだ進歩は一大医療機器産業へと発展した。さらに、走査型プローブ顕微鏡技術などによる細孔構造評価・解析法が確立され、並行して理論的・定量的アプローチによる膜透過理論が進化した。そうした膜科学と実用化技術は、米国、ドイツおよび日本が先行するが、最近は中国、インド、東南アジアおよび中東諸国の追い上げが凄まじい。血液浄化膜のイノベーションは中空糸膜とポリスルホン膜の登場であった。そこでこの総説では、膜工学(血液浄化膜)における最近の進歩についてレビューする。血液浄化膜の最新技術について生体適合性と細孔構造解析という二つの観点から検討する。企業への適正利潤は次世代医療機器開発のモチベーションであり、イノベーションの製品化に奏功する。逆の場合、当該医療機器産業の衰退に繋がり、ひいては当該医療水準の劣化にも繋がりかねない。血液浄化膜(器)は日本が誇る治療用医療機器の一つである。日本人らしい繊細な匠の技の長年の積み上げが奏功している。次の破壊的イノベーションを見据えつつ、日本発の血液浄化膜が持続的イノベーションを積み上げながら、今後も世界の血液浄化医療に貢献することを願う。(著者抄録)
  • 血液浄化膜の誕生と進化・今後への期待 Advent and Evolution of Blood Purification Membranes and Expectations for the Future
    酒井 清孝; 福田 誠; 滑川 亘希
    日本急性血液浄化学会雑誌 Japan Society for Blood Purification in Critical Care (NPO)日本急性血液浄化学会 10 (2) 73 - 88 2185-1085 2019/12 [Refereed]
     
    Thomas Grahamが拡散の原理を1854年に発見し、Dow Chemical社が1968年に中空糸型血液浄化器の量産を始めてから、血液浄化技術は大きな進化を遂げた。その中でも血液浄化膜の進歩には特筆すべきものがあり、特に高分子の合成と中空糸膜の製膜技術などの工業化学を巻き込んだ進歩は一大医療機器産業へと発展した。さらに、顕微鏡観察技術などの評価法が確立され、並行して理論的・定量的アプローチによる膜透過理論が進化した。そうした膜科学と実用化技術は、米国、ドイツおよび日本が先行するが、最近は中国、インドおよび中東諸国の追い上げがすさまじい。血液浄化膜のイノベーションは中空糸膜とポリスルホン膜の登場であった。そこでこの特別寄稿では、血液浄化膜の誕生とその後の進化についてレビューする。血液浄化膜の最新技術について生体適合性と膜透過理論という二つの観点から検討し、今後の持続的および破壊的イノベーションにも触れたい。(著者抄録)
  • Makoto Fukuda; Hitoshi Saomoto; Taisei Shimizu; Koki Namekawa; Kiyotaka Sakai
    Advanced Biomedical Engineering JAPANESE SOC MEDICAL & BIOLOGICAL ENGINEERING 8 145 - 152 2187-5219 2019/06 [Refereed]
     
    © 2019, Japanese Society for Medical and Biological Engineering. All rights reserved. A hemoconcentrator is installed as a part of cardiopulmonary bypass to concentrate the blood by removing excess water and unnecessary electrolytes from the blood diluted with myocardial protection fluid. The hemoconcentrator must remove water from diluted blood efficiently and quickly and remove proinflamma-tory cytokines and other unwanted molecules, without losing useful proteins such as albumin. Especially, the pore diameter and diameter distribution of the innermost surface greatly affect the pure water permeability and sieving coefficient of the solutes. In this study, the pore structure of the inner surface of the membrane was observed, and pore measurement of hollow fiber hemoconcentrator membranes was attempted using a scanning probe microscope (SPM). The samples studied were commercially available hemoconcentrator membranes PUREMA A and B (JMS Co. Ltd., Japan) having asymmetric structures. A SPM was used using the dynamic force microscopy (DFM), cyclic contact mode. The deep and tortuous pore structure on the inner surface of the hemoconcentrator membrane was observed for the first time using DFM. The pores had an elliptical shape, elongated in the longitudinal direction. When the elliptical area on the inner surface of the hemoconcentrator membrane was larger, pure water permeability was higher, showing a correlation between the elliptical area and membrane functions. The mean major pore diameters and minor pore diameters as well as the equivalent pore diameter calculated from the tortuous capillary pore model were consistent. Using DFM, the three-dimensional tortuous capillary pores at the inner surface of a hollow fiber hemoconcentrator membrane could be studied, and pore diameter and distribution could be measured by image analysis. The results were supported by the tortuous capillary pore model. In the future, we need to clearly show the further superior innovations or creative/ ingenious techniques related to this study. Further the state of new findings which contribute to development of a new hemoconcentrator and other semipermeable membranes will help to increase the value of this paper. This study is one of the key studies to achieve the targeted function for the transport phenomena through semipermeable membranes including hemoconcentrator.
  • ass transfer coefficient during hollow fiber dialysis membrane in a dialyzer by using dimensionless correlation equation based on the double film layer mass transfer model; compared with the single hollow fiber dialyzer
    FUKUDA MAKOTO
    第24回近畿臨床工学会 発表論文集 2017 13 - 20 2018/09 [Refereed]
  • Makoto Fukuda; Kengo Yoshimura; Koki Namekawa; Kiyotaka Sakai
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER JAPAN KK 20 (2) 145 - 151 1434-7229 2017/06 [Refereed]
     
    The objective of the present study is to evaluate the effect of filtration coefficient and internal filtration on dialysis fluid flow and mass transfer coefficient in dialyzers using dimensionless mass transfer correlation equations. Aqueous solution of vitamin B-12 clearances were obtained for REXEED-15L as a low flux dialyzer, and APS-15EA and APS-15UA as high flux dialyzers. All the other design specifications were identical for these dialyzers except for filtration coefficient. The overall mass transfer coefficient was calculated, moreover, the exponents of Reynolds number (Re) and film mass transfer coefficient of the dialysis-side fluid (k(D)) for each flow rate were derived from the Wilson plot and dimensionless correlation equation. The exponents of Re were 0.4 for the low flux dialyzer whereas 0.5 for the high flux dialyzers. Dialysis fluid of the low flux dialyzer was close to laminar flow because of its low filtration coefficient. On the other hand, dialysis fluid of the high flux dialyzers was assumed to be orthogonal flow. Higher filtration coefficient was associated with higher k(D) influenced by mass transfer rate through diffusion and internal filtration. Higher filtration coefficient of dialyzers and internal filtration affect orthogonal flow of dialysis fluid.
  • FUKUDA MAKOTO
    Advanced Biomedical Engineering Japanese Society for Medical and Biological Engineering 5 118 - 123 2187-5219 2016/06 [Refereed]
     

    The dialysis fluid flow and solute removal performance of newly developed dialyzers and a downsized dialyzer were evaluated using a dimensionless correlation equation related to the mass transfer coefficient of the dialysate-side film in a mass transfer model, which was used in quantitative analyses in our previous study. The solute removal performance is greatly dependent on the dialysis fluid flow for low molecular weight solutes. Hence, the recently developed dialyzers are based on new design concepts incorporating jackets or hollow fibers that provide an evenly distributed flow. The new dialyzers tested were APS-15SA, PES-15Sαeco, PN-140S, and NV-15U. APS-15DSplus was used as a downsized version of the APS-15SA. The dialysate-side equivalent diameter de is smaller in the APS-15DSplus than in the APS-15SA, while the other design specifications are identical for these two devices. We measured vitamin B12 clearance with the dialyzers operated at a blood-side flow rate QB = 200 mL/min, dialysate-side flow rates QD = 300–700 mL/min, and a net filtration rate QF = 0 mL/min. We then calculated the overall mass transfer coefficient. Using this value, we derived the dimensionless correlation of the Sherwood number (Sh), which includes the dialysate-side film mass transfer coefficient (kD) and Reynolds number (ReD). The exponent of ReD was approximately 0.5 for all the dialyzers. The newly developed dialyzers have various design features for improving dialysis fluid flow. Unlike previous devices, the various new designs result in a convergence of performance. A comparison of APS-15SA and the downsized APS-15DSplus showed similar dependence of kD on ReD. This finding is novel and is attributed to the similarity in the relationship between dialysate-side fluid flow and dialysate-side film mass transfer in the two devices. In both dialyzers, the jacket has a full baffle and short taper structure, and the wave design of the hollow fiber membranes is identical. However, de was smaller in APS-15DSplus. Thus, analogous design concept employing the dimensionless correlation can be adopted for downsizing a device.

  • Koki Namekawa; Masato Matsuda; Makoto Fukuda; Ami Kaneko; Kiyotaka Sakai
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER JAPAN KK 15 (2) 185 - 192 1434-7229 2012/06 [Refereed]
     
    Some dialysis patients are treated with post-hemodiafiltration (HDF); the blood viscosity of the patients who undergo post-HDF is higher than that of the patients who undergo conventional hemodialysis. This study aims to evaluate poly(N-vinyl-2-pyrrolidone) (PVP) elution from PSf dialysis membranes by varying solvents and high wall shear stress caused by blood viscosity. We tested three commercial membranes: APS-15SA (Asahi Kasei Kuraray), CX-1.6U (Toray) and FX140 (Fresenius). Dialysate and blood sides of the dialyzers were primed with reverse osmosis (RO) water and saline. RO water, saline and dextran solution (2.9 and 5.8 mPa s) were circulated in the blood side. The amount of eluted PVP was determined by 0.02 N iodometry. The hardness and adsorption force of human serum albumin (HSA) on the membrane surfaces were measured by the atomic force microscope. When wall shear stress was increased using dextran, the amount of PVP eluted by the 2.9 mPa s solution equaled that eluted by the 5.8 mPa s solution with APS-15SA and CX-1.6U sterilized by gamma rays. The amount of PVP eluted by the 5.8 mPa s solution was higher than that eluted by the 2.9 mPa s solution with FX140 sterilized by autoclaving. The wall shear stress increased the PVP elution from the surface, hardness and adsorption force of HSA. Sufficient gamma-ray irradiation is effective in decreasing PVP elution.
  • FUKUDA Makoto
    膜 日本膜学会 37 (1) 10 - 16 0385-1036 2012/01 [Refereed]
     
    Removal rate of renal toxic substances in a dialyzer depends on the mass transfer rate through a dialysis membrane and in the dialysate-side boundary films. To increasing dialysis fluid-side mass transfer rate, the most important factors are jacket structure and hollow fiber shape, so newly developed dialyzers with improved jacket structure and hollow fiber shape that optimize dialysis fluid flow have been made available on the market in recent years.
    The overall mass transfer resistance is the sum of the resistances due to the membrane itself and the thin boundary film that is formed in the fluids on both sides of the membrane (Series Boundary Film Resistance Model). The boundary film mass transfer coefficient for a fluid flowing within a straight tube has been obtained theoretically. Colburn's equation converted to mass transfer by analogy with the theoretical approximation equation that yields the boundary film coefficient of heat transmission when laminar flow occurs in a straight tube, can be used to calculate the boundary film transfer in laminar mass transfer.
    In the present study, mass transfer correlation equations between Sherwood number (Sh) containing dialysis fluidside mass transfer film coefficient and Reynolds number (Re) were formed for newly developed dialyzers. The exponents of Re were 0.62 for APS-15S whereas approximately 0.5 for the newly developed dialyzers. The dialysis fluid-side mass transfer film coefficients of the newly developed dialyzers were higher than those of the conventional dialyzer. Based on the mass transfer correlation equations, introduction of short taper, full baffle of dialyzer jacket and further wave-shaped hollow fiber improves the dialysis fluid flow.
  • MATSUDA Masato; SATO Mika; SAKATA Hiroki; OGAWA Takahisa; YAMAMOTO Ken-ichiro; YAKUSHIJI Taiji; FUKUDA Makoto; MIYASAKA Takehiro; SAKAI Kiyotaka
    人工臓器 39 (1) 31 - 32 0300-0818 2010/06 [Refereed]
  • Takehito Ogawa; Sumire Koga; Taiji Yakushiji; Masato Matsuda; Ken-ichiro Yamamoto; Hiroki Sakata; Makoto Fukuda; Takehiro Miyasaka; Kiyotaka Sakai
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER TOKYO 13 (1) 58 - 62 1434-7229 2010/04 [Refereed]
     
    Reactive oxygen species (ROS) generated during hemodialysis treatment cause dialysis complications because of the high reactivity of ROS. To prevent dialysis complications caused by oxidative stress, it is important to evaluate the generation and dismutation of ROS during hemodialysis treatment. In this study, our aim was to develop a device to determine superoxide (O(2) (-)) generated inside a dialysis hollow fiber, and also to examine whether this device could detect O(2) (-) separated from plasma using hollow fibers. Experimental apparatus was set up so that hypoxanthine (HX) solution flowed inside the hollow fibers and 2-methyl-6-p-methoxyphenylethynyl-imidazopyrazinone (MPEC) solution flowed outside the hollow fibers. Then, xanthine oxidase (XOD) solution was added to the HX solution to generate O(2) (-), and chemiluminescence resulting from the reaction of O(2) (-) with MPEC was measured with an optical fiber. Chemiluminescence intensity was measured at different HX concentrations, and the peak area of relative luminescence intensity yielded a first-order correlation with the HX concentration. Based on the relationship between HX and O(2) (-) concentrations determined by the cytochrome c reduction method, the relative luminescence intensity measured by this device was linearly dependent on the O(2) (-) concentration inside the hollow fibers. After modifications were made to the device, XOD solution injection into plasma including HX resulted in an increase in the relative luminescence intensity. We concluded that this novel device based on chemiluminescence is capable of determining aqueous O(2) (-) generated inside a hollow fiber and also of detecting O(2) (-) in plasma.
  • KOTERA Hirohisa; OHASHI Atsushi; NAKAI Shigeru; FUKUDA Makoto; ONISHI Shigeki; YASHIRO Masatomo; NABESHIMA Kunihiro; MURAKAMI Kazutaka; TOMITA Makoto; HASEGAWA Midori; HIKI Yoshiyuki; SUGIYAMA Satoshi
    Nihon Toseki Igakkai Zasshi 一般社団法人 日本透析医学会 43 (1) 55 - 60 1340-3451 2010/01 [Refereed]
     
    The concentrations of hepatitis C virus (HCV) are reported to be lower in dialysis patients than in HCV-positive non-dialysis patients. We investigated the elimination dynamics of HCV antigens (core proteins) levels pre- and post-dialysis using a regenerated cellulose membrane (CU ; AM-FP1.3), cellulose triacetate membrane (CTA ; FB-150E), polymethylmethacrylate membrane (PMMA ; BK-1.6P), or polysulfone membrane (PS ; F-70S). The rates of HCV antigen decrease by a single dialysis session were as follows 32.7&plusmn;10.5% with the F-70S, 19.0&plusmn;2.2% with the BK-1.6P, 10.4&plusmn;1.7% with the FB-150E, and 8.8&plusmn;2.2% with the AM-FP1.3. Furthermore, we compared the HCV antigen elimination ability of each dialysis membrane material in an <I>in vitro</I> experiment. We perfused albumin (Alb) containing HCV in the blood circuit connected to AM-FP1.3, FB-130U, BK-1.3P, and F-60S, and measured quantities of HCV antigen and Alb over time. The quantity of HCV antigen decreased 25.8% with the F-60S, 20.5% with the BK-1.3P, 16.0% with the FB-130U, and 10.5% with the AM-FP1.3. Furthermore, to confirm HCV adsorption to the dialysis membrane, we perfused washing solution containing non-ionic surfactant in the blood circuit used in the above investigation, and measured quantities of HCV antigen in the washing solution. The quantities of HCV antigen eluted in the washing solution were nearly equivalent to the decreases in HCV observed in the <I>in vitro</I> experiment. In conclusion, HCV in blood is adsorbed and eliminated by dialysis membranes.
  • Ken-ichiro Yamamoto; Masato Matsuda; Ayaka Hirano; Natsuo Takizawa; Shigeto Iwashima; Taiji Yakushiji; Makoto Fukuda; Takehiro Miyasaka; Kiyotaka Sakai
    ARTIFICIAL ORGANS WILEY 33 (6) 481 - 486 0160-564X 2009/06 [Refereed]
     
    Dialyzer performance strongly depends on the flow of blood and dialysis fluid as well as membrane performance. It is necessary, particularly to optimize dialysis fluid flow, to develop a highly efficient dialyzer. The objective of the present study is to evaluate by computational analysis the effects of dialyzer jacket baffle structure, taper angle, and taper length on dialysis fluid flow. We modeled 10 dialyzers of varying baffle angles (0, 30, 120, 240, and 360 degrees) with and without tapers. We also modeled 30 dialyzers of varying taper lengths (0, 12.5, 25.0, and 50.0 mm) and angles (0, 2, 4, and 6 degrees) based on technical data of APS-SA dialyzers having varying surface areas of 0.8, 1.5, and 2.5 m(2) (Rexeed). Dialysis fluid flow velocity was calculated by the finite element method. The taper part was divided into 10 sections of varying fluid resistances. A pressure of 0 Pa was set at the dialysis fluid outlet, and a dialysis fluid flow rate of 500 mL/min at the dialysis fluid inlet. Water was used as the dialysis fluid in the computational analysis. Results for dialysis fluid flow velocity of the modeled dialyzers indicate that taper design and a fully surrounded baffle are important in making the dialysis fluid flow into a hollow-fiber bundle easily and uniformly. However, dialysis fluid flow channeling occurred particularly at the outflowing part with dialyzers having larger taper lengths and angles. Optimum design of dialysis jacket structure is essential to optimizing dialysis fluid flow and to increasing dialyzer performance.
  • Satoru Kunikata; Makoto Fukuda; Ken-Ichiro Yamamoto; Yutaka Yagi; Masato Matsuda; Kiyotaka Sakai
    ASAIO JOURNAL LIPPINCOTT WILLIAMS & WILKINS 55 (3) 231 - 235 1058-2916 2009/05 [Refereed]
     
    Dialysis fluid flow and mass transfer rate of newly developed dialyzers were evaluated using mass transfer correlation equations of dialysis fluid-side film coefficient. Aqueous creatinine clearance and overall mass transfer coefficient for APS-15S (Asahi Kasei Kuraray) as a conventional dialyzer, and APS-15SA (Asahi Kasei Kuraray), PES-150S alpha (Nipro), FPX140 (Fresenius), and CS-1.61U (Toray) as newly developed dialyzers were obtained at a blood-side flow rate (Q,) of 200 ml/min, dialysis fluid-side flow rates (Q(D)) of 200-800 ml/min and a net filtration rate (Q,) of 0 ml/min. Mass transfer correlation equations between Sherwood number (Sh) containing dialysis fluid-side mass transfer film coefficient and Reynolds number (Re) were formed for each dialyzer. The exponents of Re were 0.62 for APS-15S whereas approximately 0.5 for the newly developed dialyzers. The dialysis fluid-side mass transfer film coefficients of the newly developed dialyzers were higher than those of the conventional dialyzer. Based on the mass transfer correlation equations, introduction of short taper, full baffle of dialyzer jacket and further wave-shaped hollow fiber improves the dialysis fluid flow of the newly developed dialyzers. ASAIO journal 2009; 55:231-235.
  • Koki Namekawa; Makoto Fukuda; Masato Matsuda; Yutaka Yagi; Ken-Ichiro Yamamoto; Kiyotaka Sakai
    ASAIO JOURNAL LIPPINCOTT WILLIAMS & WILKINS 55 (3) 236 - 242 1058-2916 2009/05 [Refereed]
     
    The objective of the present study was to evaluate the characteristics of protein adsorption on the inner surface of various dialysis membranes, to develop protein adsorption-resistant biocompatible dialysis membranes. The adsorption force of human serum albumin (HSA) on the inner surface of a dialysis membrane and the smoothness of the membrane were evaluated from a nanoscale perspective by atomic force microscopy. The content ratio of the hydrophilic polymer, polyvinylpyrrolidone (PVP), was determined by attenuated total reflection Fourier transform infrared spectroscopy. Nine synthetic-polymer dialysis membranes on the market made of polysulfone (PSF), polyethersulfone (PES), polyester polymer-alloy (PEPA), and ethylene vinylalcohol (EVAL) were used in the present study. The HSA adsorption force on the surface of the hydrophobic polymer PEPA membrane was higher than that on the hydrophilic polymer EVAL membrane surface. It has been considered beneficial, for decreasing the HSA adsorption force, to cover a hydrophobic polymer membrane surface with PVP. However, there were some areas on PVP-containing membrane surfaces at which much higher HSA adsorption forces were observed. The HSA adsorption force gave a nearly linear correlation with the surface roughness on the PSF membrane surface. However, the HSA adsorption force was uncorrelated with the PVP content ratio for any of the PSF membrane surfaces tested. in conclusion, protein adsorption can be minimized by the use of dialysis membranes made of hydrophobic polymers containing PVP with a smooth surface. ASAIO journal 2009; 55:236-242.
  • Masato Matsuda; Mika Sato; Hiroki Sakata; Takahisa Ogawa; Ken-ichiro Yamamoto; Taiji Yakushiji; Makoto Fukuda; Takehiro Miyasaka; Kiyotaka Sakai
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER TOKYO 11 (3) 148 - 155 1434-7229 2008/09 [Refereed]
     
    When uremic blood flows through dialyzers during hemodialysis, dialysis membrane surfaces are exposed to shear stress and internal filtration, which may affect the surface characteristics of the dialysis membranes. In the present study, we evaluated changes in the characteristics of membrane surfaces caused by shear stress and internal filtration using blood substitutes: water purified by reverse osmosis and 6.7 wt% dextran70 solution. We focused on the levels of a hydrophilic modifier, polyvinylpyrrolidone (PVP), on the membrane surface measured by attenuated total reflectance Fourier transform infrared spectroscopy. Experiments involving 4 h dialysis, 0-144 h shear-stress loading, and 4 h dead-end filtration were performed using polyester-polymer alloy (PEPA) and polysulfone (PS) membranes. After the dialysis experiments with accompanying internal filtration, average PVP retention on the PEPA membrane surface was 93.7% in all areas, whereas that on the PS membrane surface was 98.9% in all areas. After the shear-stress loading experiments, PVP retention on the PEPA membrane surface decreased as shear-stress loading time and the magnitude of shear stress increased. However, with the PS membrane, PVP retention scarcely changed. After the dead-end filtration experiments, PVP retention decreased in all areas for both PEPA and PS membranes, but PVP retention on the PEPA membrane surface was lower than that on the PS membrane surface. PVP on the PEPA membrane surface was eluted by both shear stress and internal filtration, while that on the PS membrane surface was eluted only by internal filtration.
  • Masato Matsuda; Ken-ichiro Yamamoto; Taiji Yakushiji; Makoto Fukuda; Takehiro Miyasaka; Kiyotaka Sakai
    JOURNAL OF MEMBRANE SCIENCE ELSEVIER SCIENCE BV 310 (1-2) 219 - 228 0376-7388 2008/03 [Refereed]
     
    Hydrophilizing synthetic polymer dialysis membranes with polyvinylpyrrolidone (PVP) play an important role for inhibition of protein adsorption on membrane surface. In the present study, the effect of PVP on protein adsorption was evaluated from a nano-scale perspective. Swelling behavior of PVP present on wet polysulfone (PS)/PVP film surfaces was observed by atomic force microscopy (AFM). Fibrinogen and human serum albumin (HSA) were immobilized on the tip of AFM probes, with which a force-curve between protein and wet PS/PVP film surface was measured by AFM while scanning in order to visualize two-dimensional protein adsorbability on film surfaces. Furthermore, HSA adsorbability on non-PVP containing PEPA dialysis membrane (FLX-15GW) and PVP containing PEPA dialysis membrane (FDX-150GW) was evaluated by the AFM force-curve method. As a result, PS/PVP film surface was completely covered with hydrated and swollen PVP at 5 wt% or more PVP content. Protein adsorbability on PS/PVP film surfaces decreased greatly with increasing content of PVP. The adsorption of HSA was inhibited by the presence of PVP on film surfaces more significantly than that of more hydrophobic fibrinogen. HSA adsorbability on wet FLX-15GW dialysis membrane surface was 428+/-174 pN whereas that on wet FDX-150GW dialysis membrane surface was 42+/-29 pN. (C) 2007 Elsevier B.V. All rights reserved.
  • 透析器の軸方向および断面方向における親水化剤溶出性
    佐藤 美佳; 松田 雅人; 薬師寺 大二; 福田 誠; 宮坂 武寛; 山本 健一郎; 酒井 清孝
    医工学治療 (NPO)日本医工学治療学会 19 (4) 251 - 255 1344-1221 2007/12 [Refereed]
     
    透析で用いられている合成高分子膜のうち、ポリスルホン(PS)とポリエステル系ポリマアロイ(PEPA)は、親水化剤であるポリビニルピロリドン(PVP)を添加することによって膜表面を親水化し、生体適合性の向上を図っている。しかし、透析により生じる中空糸膜表面のPVP分布の変化を定量的に検討した例はない。そこで、本研究では、透析器内の中空糸膜を軸方向および断面方向のいくつかのエリアに分け、各エリアにおける膜表面PVP残存率を測定し、PVPの溶出性を評価した。APS-15EX(試作品:PS膜、旭化成メディカル)およびFDX-15GW(PEPA膜、日機装)の透析器を用いて、血液側流量200mL/min、透析液側流量500mL/minで4時間透析を行った。このとき、血液側には血液と同粘度を有する6.7wt%デキストラン70水溶液、透析液側には逆浸透水を用いた。透析終了後に透析器ジャケットを取り外し、各エリア(透析器軸方向に3分割、断面方向に12分割、合計36エリア)から中空糸を取り出した。全反射減衰フーリエ変換赤外分光法(FTIR/ATR)で透析前後の中空糸膜内表面におけるPVP残存率を測定した。APS-15EXおよびFDX-15GWのいずれの透析器も、透析によって膜表面PVP残存率はすべてのエリアで減少しており、すべてのエリアでPVPが溶出したことがわかった。なお、APS-15EXとFDX-15GWの平均PVP残存率は、それぞれ94.1%、90.8%となり、APS-15EXの方が若干高いPVP残存率を示した。さらに、断面方向と軸方向で比較したところ、いずれの透析器も次のように同様の傾向を示した。断面方向では各断面にPVP残存率の偏りがみられた。軸方向では、中空糸束中央部に比較して、内部濾過量の多い中空糸束両端部においてPVP残存率が著しく低下した。特に、濾過が生じている血液出口部において、この傾向は顕著であった。(著者抄録)
  • Ken-Ichiro Yamamoto; Masato Matsuda; Masashi Okuoka; Taiji Yakushiji; Makoto Fukuda; Takehiro Miyasaka; Yutaka Matsumoto; Kiyotaka Sakai
    JOURNAL OF MEMBRANE SCIENCE ELSEVIER SCIENCE BV 302 (1-2) 115 - 118 0376-7388 2007/09 [Refereed]
     
    The antioxidation property of vitamin E-coated dialysis membrane is effective for reduction of oxidative stress. Effect of amount of vitamin E coating on antioxidation property has been poorly understood yet. In the present study, we evaluated a relationship between amount of vitamin E coating and antioxidation property using a superoxide probe of 2-methyl-6-p-methoxyphenylethynylimidazopyrazinone (MPEC) by the optical fiber method to determine optimum amount of vitamin E coating and to improve antioxidation property of the vitamin E-coated dialysis membrane. Furthermore, from the viewpoint of reuse, we examined recovery of oxidized vitamin E by vitamin C treatment. In conclusion, it is necessary to coat polysulfone dialysis membranes with vitamin E at over 74 mg/m(2). The antioxidation property is recoverable by treating dialysis membrane containing oxidized vitamin E with vitamin C. By administrating vitamin C, higher antioxidation property may be realized with a small amount of vitamin E coating. (c) 2007 Elsevier B.V. All rights reserved.
  • Ken-Ichiro Yamamoto; Hiroaki Matsukawa; Taiji Yakushiji; Makoto Fukuda; Tatsuo Hiyoshi; Kiyotaka Sakai
    ASAIO JOURNAL LIPPINCOTT WILLIAMS & WILKINS 53 (1) 36 - 40 1058-2916 2007/01 [Refereed]
     
    Rexeed was developed by Asahi Kasei Medical using wave-shaped hollow fibers, a full baffle, and a short taper housing to improve dialysate flow. The present study is clarifies improvement in dialysate flow with Rexeed-15 compared with that of a conventional dialyzer. Dialysate flow was evaluated by the pulse-response method. Dialysate pressure and tracer concentration were measured at a blood-side flow rate (Q(B)) of 200 ml/min, a dialysate-side flow rate (Q(D)) of 500 ml/min, and a net filtration rate (Q(F)) of 0 ml/min using needles placed in the test dialyzer. Dialyzer performance was evaluated by measuring urea and vitamin B-12 clearance at Q(B) = 200 and 400 ml/min, Q(D) = 300-800 ml/min, and Q(F) = 0 ml/min. In the conventional dialyzer, dialysate channeling was observed. In contrast, Rexeed-15 had a uniform dialysate flow. Urea and vitamin B-12 clearance with Rexeed-15 was slightly sensitive to Q(D). The overall mass transfer coefficient for urea with Rexeed-15 was more than 50% higher than that of the conventional dialyzer, indicating the possibility of reduced dialysate usage with Rexeed. Rexeed has a highly optimal dialysate flow, due to the wave-shaped hollow fibers and the new housing, and gives increased clearance for lower-molecular-weight substances.
  • Ken-ichiro Yamamoto; Masayo Hayama; Masato Matsuda; Taiji Yakushiji; Makoto Fukuda; Takehiro Miyasaka; Kiyotaka Sakai
    JOURNAL OF MEMBRANE SCIENCE ELSEVIER SCIENCE BV 287 (1) 88 - 93 0376-7388 2007/01 [Refereed]
     
    The tortuous capillary pore diffusion model (TCPDM) has been used for estimating diffusive and pure water permeability from simple structure parameters such as pore diameter, surface porosity, wall thickness and tortuosity. The validity of this model for evaluation of homogeneous membrane has been already confirmed. Recently, there is a trend toward the use of asymmetrical dialysis membranes made of synthetic polymer such as poly(acrylonitrile) (PAN), polysulfone (PS) and a polyethersulfone polyarylate (PEPA) blend polymer. The purpose of the present study is to apply the TCPDM to evaluation of commercially available hollow-fiber dialysis membranes with asymmetrical structures by simplifying them to a double-layer membrane. The TCPDM is capable of estimating pore tortuosity of asymmetrical dialysis membranes having skin and supporting layers from data on membrane thickness, pore diameter, pure water permeability and water content. Values for diffusive permeability obtained by the TCPDM are in a good agreement with experimental data. This TCPDM model is useful for evaluation of not only homogeneous membrane but also asymmetrical membrane. (c) 2006 Elsevier B.V. All rights reserved.
  • Ken-ichiro Yamamoto; Shigeto Iwashima; Mai Hasegawa; Masato Matsuda; Kiyotaka Sakai; Taiji Yakushiji; Makoto Fukuda; Takehiro Miyasaka
    NEPHROLOGY DIALYSIS TRANSPLANTATION OXFORD UNIV PRESS 22 122 - 123 0931-0509 2007 [Refereed]
  • Makoto Fukuda; Miwa Miyazaki; Satoshi Uezumi; Makoto Yoshida
    Journal of Artificial Organs 9 (3) 192 - 198 1434-7229 2006/09 [Refereed]
     
    Dialyzer performance seems to greatly depend on the hollow-fiber membrane performance, the morphology of the hollow-fiber membrane bundles (e.g., wave-shaped hollow-fiber membrane bundles), and the design of the dialyzer housing. Consequently, we developed the APS dialyzer APS-SA series, equipped with wave-shaped hollow-fiber membrane bundles as an optimal three-dimensional morphology along with new housings, to realize enhanced dialysis performance. Incorporation of a new type of housing, including a full baffle structure and a short taper section, and a new type of morphology for the hollow-fiber membrane bundles have been verified to allow the dialysate to diffuse uniformly along the full baffle panel around the circumference and to fully permeate into the core of the hollow-fiber bundle. As a result, the APS-SA series has been proved to have achieved enhanced diffusion performance and increased clearance of small molecule solutes such as urea and creatinine, compared with conventional dialyzers. This series is expected to provide increased Kt/V values and dialysate-saving performance in future clinical use. © 2006 The Japanese Society for Artificial Organs.
  • Ken-Ichiro Yamamoto; Michihito Hiwatari; Fukashi Kohori; Kiyotaka Sakai; Makoto Fukuda; Tatsuo Hiyoshi
    Journal of Artificial Organs 8 (3) 198 - 205 1434-7229 2005/09 [Refereed]
     
    For efficient removal of large molecular weight solutes by dialysis, several types of internal filtration-enhancing dialyzers (IFEDs) are commercially available. However, in a pressure-driven membrane separation process (i.e., filtration), membrane fouling caused by adhesion of plasma proteins is a severe problem. The objective of the present study is to investigate the effects of internal filtration on membrane fouling based on the membrane's pure-water permeability, diffusive permeability, and sieving coefficient. Hemodialysis experiments were performed with two different dialyzers, IFEDs and non-IFEDs. Local membrane fouling in each dialyzer was evaluated by measuring the pure-water permeability, the diffusive permeability, and the sieving coefficient of native membranes and membranes treated with bovine blood. The effects of packing ratio on dialysate flow pattern were also evaluated by measuring the time required for an ion tracer to reach electrodes placed in the dialyzers. In the IFED, membrane fouling caused by protein adhesion is increased because of enhanced internal filtration only at the early stage of dialysis, and this fouling tends to occur only near the dialysate outlet port. However, enhanced internal filtration has little effect on measured membrane transfer parameters. © The Japanese Society for Artificial Organs 2005.
  • 福田 誠; 宮崎 美和; 上住 敏士; 日吉 辰夫; 内 幸彦; 藤村 崇保
    人工臓器 一般社団法人 日本人工臓器学会 33 (3) 288 - 290 0300-0818 2004/12
  • Takayasu Fujimura; Yukihiko Uchi; Makoto Fukuda; Miwa Miyazaki; Satoshi Uezumi; Tatsuo Hiyoshi
    Journal of Artificial Organs 7 (3) 149 - 154 1434-7229 2004/09 [Refereed]
     
    Accumulated low molecular weight proteins in hemodialysis patients require a high-flux dialyzer. There have been several methods proposed for enhancing internal filtration, including narrowing the inside diameter of the hollow fibers, lengthening the fibers, and increasing the fiber density ratio. We tried to enhance the internal filtration by increasing the pressure drop in the dialysate compartment through increasing the fiber density ratio. If the fiber density ratio is too high, however, an irregular dialysate path may result, thus decreasing dialysis performance. Therefore, we took note of the shape of the inner housing and added a short taper structure, which improved the dialysate path dramatically. Consequently, we developed an internal filtration-enhanced dialyzer (APS-Prototype) to improve dialysis performance. The internal filtration rate in water (measured by Doppler ultrasound) was 13.2l/session for the APS-Prototype and 5.3l/session for the APS-15E. The amount of α1-microglobulin (α1-MG) in bovine plasma was 0.34 g for the APS-Prototype and 0.11 g for the APS-15E. In addition, the amount of α1-MG in vivo was 29.0% ± 5.8% for the APS-Prototype, significantly higher than that for the APS-15E (13.6% ± 1.9%). The desirable loss of albumin is 2-4 g in hemodiafiltration, and it was 3.92 ± 1.03 g for the APS-Prototype. The prototype showed excellent solute removal performance with no clinical or engineering problems.
  • Kei Ishiwata; Kenichiro Yamamoto; Fukashi Kohori; Kiyotaka Sakai; Makoto Fukuda; Tatsuo Hiyoshi
    Journal of Artificial Organs 5 (4) 251 - 256 1434-7229 2002 [Refereed]
     
    In a hollow-fiber dialyzer, uremic toxins are removed by diffusion and convection, which are influenced by the dialysate flow patterns in the dialyzer. Recently available high-performance dialyzers have complicated dialysate flow patterns, because both positive filtration and negative filtration occur. The objective of the present study was to evaluate dialysate flow in high-performance dialyzers experimentally. Glass-coated 0.1 mmφ platinum electrodes were used for the electrode counter and the working electrode. A counter electrode was placed at the inlet of the dialyzer, and working electrodes were placed at 20 different positions. A voltage of 0.5V was applied between the counter and the working electrodes with a potentiostat, and after the dialyzer was filled with water purified by reverse osmosis, 0.9% NaCl solution was caused to flow. The time at which the 0.9% NaCl solution reached each working electrode from the counter electrode was then measured at a dialysate-side flow rate of 300ml/min and blood-side flow rates of 0 and 200 ml/min. It was found that in dialyzers with high permeability to pure water, dialysate flow was affected by both positive and negative filtration. A comparison was then made between the experimental results and the results of simulation by the finite element method at positions at which positive and negative filtration occurred, good agreement was obtained. This method makes possible the experimental evaluation of dialysate flow in a high-performance dialyzer in which positive and negative filtration occur.
  • M. Fukuda
    Japanese Journal of Artificial Organs 29 411 - 418 0300-0818 2000/12 [Refereed]
     
    〈BIOREX AM-BC-X〉 is a new cellulosic membrane whose pore size is distributed asymmetrically in the membrane wall. The objectives of the present study are to clarify the phenomenon of solute transfer occurring inside dialyzers made from asymmetric membranes, to examine the structure of the asymmetric membrane capable of suppressing the inflow of endotoxins from dialysate, and thereby to contribute to the design of a more effective dialysis membrane. Using membranes that have tight layers on both sides (drum-shaped membrane, 〈BIOREX AM-BC-X〉 with the outer one tighter, solutes are more easily transferred from the inside out than from the outside in, leading to effective removal of pathogenic substances from blood and a significant lowering of endotoxin inflow from the dialysate. In asymmetric dialysis membranes, the anisotropy of solute permeability is caused by the difference in the amount of solute transfer due to filtration from the inside out and from the outside in.
  • 渡邉 哲夫; 西田 治; 福田 誠; 日吉 辰夫
    膜 日本膜学会 25 (5) 233 - 235 0385-1036 2000/09 [Refereed]
  • FUKUDA M; HIYOSHI T; SAKAI K; KOKUBO K
    Journal of the Japanese Society for Artificial Organs and Tissues JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 29 (2) 411 - 418 1883-6097 2000 [Refereed]
     
    «BIOREX AM-BC-X» is a new cellulosic membrane whose pore size is distributed asymmetrically in the membrane wall. The objectives of the present study are to clarify the phenomenon of solute transfer occurring inside dialyzers made from asymmetric membranes, to examine the structure of the asymmetric membrane capable of suppressing the inflow of endotoxins from dialysate, and thereby to contribute to the design of a more effective dialysis mem-brane. Using membranes that have tight layers on both sides (drum-shaped membrane), «(BIOREX AM-BC-X») with the outer one tighter, solutes are more easily transferred from the inside out than from the outside in, leading to effective removal of pathogenic substances from blood and a significant lowering of endotoxin inflow from the dialysate. In asymmetric dialysis membranes, the anisotropy of solute permeability is caused by the difference in the amount of solute transfer due to filtration from the inside out and from the outside in.
  • N Tsunoda; K Kokubo; K Sakai; M Fukuda; M Miyazaki; T Hiyoshi
    ASAIO JOURNAL LIPPINCOTT WILLIAMS & WILKINS 45 (5) 418 - 423 1058-2916 1999/09 [Refereed]
     
    A great deal of research has been conducted focusing on membrane materials with reference to their blood compatibility, but blood compatibility is influenced both by the material used in membranes and their structure, and by the flow conditions at the membrane surface. Accordingly, the relationship between membrane surface roughness and hemocompatibility has been evaluated using five types of membranes of differing surface roughness by evaluating the inner surfaces of the hollow fibers by atomic force microscopy (AFM) and by measuring platelet adhesion ratios using bovine blood. The yield stress, which equates to flow characteristics, was also evaluated using a glycerol suspension of polymethylmethacrylate (PMMA), a Bingham fluid. It was found that membranes having rough surfaces had high platelet adhesion ratios and poor hemocompatibility, whereas those with smoother surfaces had lower platelet adhesion ratios and better hemocompatibility. Measurement of the yield stresses for these membranes revealed higher values far those with rough surfaces, and lower values for those with smoother polyethylene glycol (PEG) grafted surfaces. This suggests that flow conditions at the membrane surface differ according to its surface roughness, and that this difference in flow conditions also influences hemocompatibility.
  • M Fukuda; M Miyazaki; T Hiyoshi; M Iwata; T Hongou
    JOURNAL OF APPLIED POLYMER SCIENCE JOHN WILEY & SONS INC 72 (10) 1249 - 1256 0021-8995 1999/06 [Refereed]
     
    The new biocompatible cellulosic membrane (AM-BC-F [AM-BIO-HX], Asahi-Medical Co. Ltd., Tokyo, Japan) has been developed, which has a higher flux than conventional membranes and more excellent antithrombogenicity because of its smoother membrane surface. The roughness of the inner surface of the AM-BC-F membrane was smaller than that of conventional membranes, as observed by Atomic Force Microscopy, because it was produced by the newly developed spinning method of cuprammonium cellulose solution, which has a different composition from that of a conventional cuprammonium cellulose solution. The degree of platelet adhesion (number of platelets adhered) on the membrane surface was evaluated in vitro by the measurement of the amount of the LDH released from the adhered platelets on the membrane surface after contact with fresh blood of Japanese male white rabbits weighing 2.5-3.0 kg. The number of platelets adhered of AM-BC-F was far smaller than that of conventional membranes. It was deduced from the smoother surface of the membrane. It can be expected that AM-BC-F will have an excellent antithrombogenicity on a dynamic state during actual dialysis treatments, because it is considered that the shearing stress of blood on the inner surface and the interaction between platelets and the membrane surface are less than that of conventional membrane2s. (C) 1999 John Wiley & Sons, Inc.
  • FUKUDA MAKOTO; MIYAZAKI MAKOTO; HIYOSHI TATSUO
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 28 (2) 458 - 464 1883-6097 1999/04 [Refereed]
     
    A new biocompati ble cellulosic membrane «BIOREX AM-BC-F» has been developed, which has a higher flux than conventional membranes and more excellent anti-thrombogenicity. These improvements are due to the membrane's smoother surface. The inner surface of the «AM-BC-F» membrane was less rough than that of conventional membranes, an observation conducted by Atomic Force Microscopy. The membrane was produced by the newly developed cuprammonium cellulose solution spinning, which has a different composition from that of a conventional cuprammonium cellulose solution. The degree of platelet adhesion (number of platelet adhered) on the membrane surface was evaluated in vitro. The number of platelet that adhered to the «AM-BC-F» was far smaller than that of conventional membranes. It was thought that these results were due to the membrane's smoother surface.
  • OGAWA HAJIME; MATSUYAMA IEHISA; FUKUDA MAKOTO; MIYAZAKI MAKOTO; HIYOSHI TATSUO; NISHIDA OSAMU
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 28 (1) 138 - 144 1883-6097 1999/02 [Refereed]
     
    «BIOREX AM-BC-X» is a new cellulosic membrane with a symmetrical gradient morphology in pore size distribution in the membrane wall. The pore radius surrounding the middle part of the membrane wall is larger than that of the «BIOREX AM-BC-F». The inner surface is as smooth as that of the «AM-BC-F». «BIOREX AM-BC-X» has some advantages required for hemodialysis membranes, (1) reduced mass transfer resistance, (2) reduced backfiltration of pyrogens from dialysate side into blood side, (3) reduced albumin penetration and adhesion onto membrane wall, (4) adequate mechanical strength, compared with symmetrical, gradient, reversed gradient pore structure membranes, respectively. These characteristic advantages are brought about by the symmetrical gradient pore structure.
  • H. Ogawa; I. Matsuyama; M. Fukuda; M. Miyazaki; T. Hiyoshi; O. Nishida
    Japanese Journal of Artificial Organs 28 138 - 144 0300-0818 1999/01 [Refereed]
     
    <BIOREX AM-BC-X> is a new cellulosic membrane with a symmetrical gradient morphology in pore size distribution in the membrane wall. The pore radius surrounding the middle part of the membrane wall is larger than that of the <BIOREX AM-BC-F>. The inner surface is as smooth as that of the <AM- BC-F>. <BIOREX AM-BC-X> has some advantages required for hemodialysis membranes, (1) reduced mass transfer resistance, (2) reduced backfiltration of pyrogens from dialysate side into blood side, (3) reduced albumin penetration and adhesion onto membrane wall, (4) adequate mechanical strength, compared with symmetrical, gradient, reversed gradient pore structure membranes, respectively. These characteristic advantages are brought about by the symmetrical gradient pore structure.
  • M. Fukuda; M. Miyazaki; T. Hiyoshi
    Japanese Journal of Artificial Organs 28 458 - 464 0300-0818 1999/01 [Refereed]
     
    A new biocompatible cellulosic membrane (BIOREX AM-BC-F) has been developed, which has a higher flux than conventional membranes and more excellent anti-thrombogenicity. These improvements are due to the membrane's smoother surface. The inner surface of the (AM-BC-F) membrane was less rough than that of conventional membranes, an observation conducted by Atomic Force Microscopy. The membrane was produced by the newly developed cuprammonium cellulose solution spinning, which has a different composition from that of a conventional cuprammonium cellulose solution. The degree of platelet adhesion (number of platelet adhered) on the membrane surface was evaluated in vitro. The number of platelet that adhered to the <AM-BC-F> was far smaller than that of conventional membranes. It was thought that these results were due to the membrane's smoother surface.
  • M Fukuda; K Kokubo; K Sakai; G Onishi; K Takewaki; T Hiyoshi
    BIOCHEMICAL ENGINEERING JOURNAL ELSEVIER SCIENCE SA 2 (2) 127 - 136 1369-703X 1998/11 [Refereed]
     
    The objectives of the present study are to clarify the phenomenon of solute transfer occurring inside dialyzers made from asymmetric membranes, to examine the structure of asymmetric membranes capable of suppressing the inflow of endotoxins from the dialysate, and thereby to contribute to the design of a more effective dialysis membrane. Using membranes that have tight layers on both sides (drum-shaped membrane) with the outer one tighter, solutes are more easily transferred from the inside out than from the outside in, leading to effective removal of pathogenic substances from the blood and a significant lowering of endotoxin inflow from the dialysate. The anisotropy of solute permeability of asymmetric dialysis membranes is caused by the difference in the amount of solute transfer due to filtration from the inside out and from the outside in. (C) 1998 Elsevier Science S.A. All rights reserved.
  • TSUNODA NANAE; KOKUBO KEN'ICHI; SAKAI KIYOTAKA; FUKUDA MAKOTO; MIYAZAKI MAKOTO; HIYOSHI TATSUO
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 27 (2) 475 - 479 1883-6097 1998/04 [Refereed]
     
    Biocompatibility of dialysis membrane has been studied directing our attention to difference in membrane material. To clarify a membrane of thrombus formation, it should be evaluated with respect to not only membrane material but also flow characteristics on membrane surface depending on surface roughness. Platelet adhesion on the membrane surface was measured using 5 dialysis membranes of different surface roughneses. Bovine blood (500ml) added with trisodium citrate dihydrate (approximately 2g) as an anticoagulant was circulated in a test dialyzer at a flow rate of 200ml/min. Pressure drop and flow rate of PMMA (particle diameter: 1μm) suspension in glycerol(Bingham fluid)(glycerol: PMMA=2: 1 by weight ratio) were measured to determine yield stress. The yield stress of the membranes and increased with surface roughness. The amount of platelet adhesion increased with yield stress, indicating that the platelet adhesion depends on surface roughness.
  • FUKUDA MAKOTO; MIYAZAKI MAKOTO; HIYOSHI TATSUO; HONGO TOMOKO; UESAKA MASATOSHI; MAEKAWA TOMOTERU; YABUSHITA HAJIME; MATSUYAMA IEHISA; OGAWA HAJIME
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 27 (1) 212 - 216 1883-6097 1998/02 [Refereed]
     
    ((BIOREX AM-BC-F)) is the new cellulosic membrane of which the inner surface is smoother than that of conventional cellulosic membrane, and alkyl ether carboxylic acid(polyethylene glycol) chain is grafted onto the inner surface of the membrane. ((AM-BC-F)) is produced by the new spinning method ((FIS(Fine Inner Surface) Technology)). It can be expected that it reduces hydrodynamic resistance between blood and the membrane. And it reduces complement activation in vivo, because rapid movement of the flexible PEG chain, ((Diffusive Layer)), leads to less interaction between blood and membrane.
  • M. Fukuda; M. Miyazaki; T. Hiyoshi
    Japanese Journal of Artificial Organs JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 27 (1) 212 - 216 0300-0818 1998/01 [Refereed]
     
    <<BIOREX AM-BC-F>> is the new cellulosic membrane of which the inner surface is smoother than that of conventional cellulosic membrane, and alkyl ether carboxylic acid(polyethylene glycol) chain is grafted onto the inner surface of the membrane. <<AM-BC-F>> is produced by the new spinning method <<FIS(Fine Inner Surface) Technology>>. It can be expected that it reduces hydrodynamic resistance between blood and the membrane. And it reduces complement activation in vivo, because rapid movement of the flexible PEG chain, <<Diffusive Layer>>, leads to less interaction between blood and membrane.
  • N. Tsunoda; K. Kokubo; K. Sakai; M. Fukuda; T. Hiyoshi
    Japanese Journal of Artificial Organs 27 475 - 479 0300-0818 1998/01 [Refereed]
     
    Biocompatibility of dialysis membrane has been studied directing our attention to difference in membrane material. To clarify a membrane of bus formation, it should be evaluated with respect to not only membrane material but also flow characteristics on membrane surface depending on surface roughness. Platelet adhesion on the membrane surface was measured using 5 dialysis membranes of different surface roughneses. Bovine blood (500 ml) added with trisodium citrate dihydrate (approximately 2 g) as an anticoagulant was circulated in a test dialyzer at a flow rate of 200 ml/min. Pressure drop and flow rate of PMMA (particle diameter : 1 μm) suspension in glycerol (Bingham fluid) (glycerol : PMMA = 2: 1 by weight ratio) were measured to determine yield stress. The yield stress of the membranes and increased with surface roughness. The amount of platelet adhesion increased with yield stress, indicating that the platelet adhesion depends on surface roughness.
  • ONISHI TSUYOSHI; KOKUBO KEN'ICHI; SAKAI KIYOTAKA; FUKUDA MAKOTO; HIYOSHI TATSUO
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 26 (3) 734 - 738 1883-6097 1997/06 [Refereed]
     
    Highly permeable dialysis membranes of asymmetrical structure were developed to mitigate amyloidosis which patients undergoing long-term dialysis treatment caught. Filtration and backfiltration through the membranes play an important part in solute transport. The rejections of the asymmetrical membranes are different between transport directions. To design high performance membranes, it is important to clarify the effects of the difference in rejection between directions of solute transport. Rejection and overall mass transfer coefficient of dextran were determined by filtration and counter-current dialysis experiments to compare transport characteristics of gradient structure membranes having a skin layer inside the wall of hollow fibers with those of the reverse gradient structure membranes having a skin layer outside. Overall mass transfer resistance and rejection of the gradient structure membranes are lower for transport from outside to inside than for that from inside to outside, indicating that solutes are easy to move from outside to inside. On the other hand, those of the reverse gradient structure membranes are lower for transport from inside to outside than for that from outside to inside, indicating that solutes are easy to move from inside to outside. The solute transport characteristics of the reverse gradient structure membranes are suitable for dialysis treatment. We conclude that thee overall mass transfer coefficient of the asymmetrical dialysis membrane increases by providing them with differences in rejection between transport directions.
  • MIYAZAKI MAKOTO; FUKUDA MAKOTO; HIYOSHI TATSUO
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 26 (1) 165 - 170 1883-6097 1997/02 [Refereed]
     
    It is well known that performances of hemodialysis membrane depend on its pore structure. Herein the new pore structure membrane‹PT-X› is proposed. ‹PT-X› has a symmetrical gradient morphology in pore size distribution in the membrane wall. The pore radius around middle part of the membrane wall is larger than that of surface parts. ‹PT-X› has some advantages required for hemodialysis membranes, (1) reduced mass transfer resistance, (2) reduced backfiltration of pyrogens from dialysate side into blood side, (3) reduced albumin penetration and adhesion onto membrane wall, (4) adequate mechanical strength, compared with symmetrical, gradient, reversed gradient and symmetrical pore structure membranes, respectively. These characteristic advantages are brought about for the symmetrical gradient pore structure.
  • HIYOSHI Tatuo; MIYAZAKI Makoto; FUKUDA Makoto
    MEMBRANE THE MEMBRANE SOCIETY OF JAPAN 22 (2) 74 - 80 0385-1036 1997 [Refereed]
     
    Most of requirements for hemodialysis hollow fiber membranes depend on their micro pore structure and distribution. Therefore, not only the averaged pore radius but also the pore radius distribution should be noted in the optimal design of hollow fiber hemodialysis membranes. Herein some advantageous characteristics of newly developed cellulose hemodialysis membrane, pore radius distribution pattern of which may be so called "symmetricall gradient structure", are presented with those of the conventional and well known homogeneous, gradient, and reverse gradient structure membranes.
  • M. Miyazaki; M. Fukuda; T. Hiyoshi
    Japanese Journal of Artificial Organs 26 165 - 170 0300-0818 1997/01 [Refereed]
     
    It is well known that performances of hemodialysis membrane depend on its pore structure. Herein the new pore structure membrane <PT-X> is proposed <PT-X> has a symmetrical gradient morphology in pore size distribution in the membrane wall. The pore radius around middle part of the membrane wall is larger than that of surface parts <PT-X> has some advantages requied for hemodialysis membranes, (1) reduced mass transfer resistance, (2) reduced backfiltration of pyrogens from dialysate side into blood side, (3) reduced albumin penetration and adhesion onto membrane wall, (4) adequate mechanical strength, compared with symmetrical, gradient, reversed gradient and symmetrical pore structure membranes, respectively. These characteristic advantages are brought about for the symmetrical gradient pore structure.
  • T KANAMORI; M FUKUDA; K SAKAI
    JOURNAL OF COLLOID AND INTERFACE SCIENCE ACADEMIC PRESS INC JNL-COMP SUBSCRIPTIONS 171 (2) 361 - 365 0021-9797 1995/05 [Refereed]
     
    The distribution volume of water contained in 31 hemodialysis membranes made from seven polymers was measured by three different methods, Water contained in the membranes was classified into three groups according to thermal mobility of the molecules, Structural analysis of the membranes was feasible through determining proportion of nonfreezing water to total water contained in the membranes. (C) 1995 Academic Press, Inc.
  • T KANAMORI; K SAKAI; M FUKUDA; Y YAMASHITA
    JOURNAL OF APPLIED POLYMER SCIENCE JOHN WILEY & SONS INC 55 (11) 1601 - 1605 0021-8995 1995/03 [Refereed]
     
    Swelling layers formed by poly(ethylene glycol) (PEG) chains grafted onto surfaces of a cellulosic membrane are known to improve hemocompatibility of the membrane. Three types of hemodialysis membranes were derived from the same regenerated-cellulose hollow-fiber membrane by grafting PEG with different formulas onto the surfaces to clarify the influence of the grafted PEG chains on solute permeability of the membranes. Determination of volume fractions of nonfreezing water contained in the membranes by differential scanning calorimetry revealed that most of the PEG chains were grafted onto the external surfaces and less into the pores in the membranes. Permeability of vitamin B-12 for the PEG-grafted membranes except for the one with the shortest PEG chains was reduced as compared with the original membrane, while that of tritium-labeled water for all the PEG-grafted membranes was the same as that of the original membrane. Structural parameters only of the PEG-grafted membrane with the largest alkyl groups at the terminal of the PEG chains were different from those of the other PEG grafted and original membranes. The shorter PEG chains with the larger terminal alkyl groups are suitable for grafting onto a cellulosic membrane to increase hemocompatibility of the membrane without significant reduction in the solute permeability of the membrane. (C) 1995 John Wiley & Sons, Inc.
  • T KANAMORI; K SAKAI; T AWAKA; M FUKUDA
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN SOC CHEMICAL ENG JAPAN 27 (6) 830 - 832 0021-9592 1994/12 [Refereed]
  • T KANAMORI; K SAKAI; T AWAKA; M FUKUDA
    JOURNAL OF MEMBRANE SCIENCE ELSEVIER SCIENCE BV 88 (2-3) 159 - 165 0376-7388 1994/03 [Refereed]
     
    Absorbancy of a solution in the narrow lumen of a tubular membrane under dialysis is continuously measurable with a newly-developed apparatus using quartz optical fibers. The solute permeability of the membrane was determined by calculating time-dependent changes in the absorbancy measured with the apparatus by the mathematical solution derived for unsteady-state concentration profiles in an infinitely long composite cylinder. This method was independent of convective mass transport and osmotic flow through membranes, leading to superiority to ordinary techniques with respect to accuracy.
  • KANAMORI T; SAKAI K
    Jinko Zoki 一般社団法人 日本人工臓器学会 23 (3) 578 - 584 0300-0818 1994 [Refereed]
     
    Intramembrane diffusivity and water permeability are essential for characterization of dialysis membranes. The physical state of water present in the membrane may affect the solute diffusivity because solutes diffuse into only a fraction of water in the membrane and water inside the membrane changes places with that outside the membrane. Water content was measured in 31 dialysis membranes made of 7 polymers. The physical state of water was determined from data on water content by the conventional method and the differential scanning calorimetry and on partition coefficient measured by the use of tritium-labeled water. Three kinds of water state of varying molecular mobilities were found in the membranes and their volume ratio was dependent on the membrane material. The mechanism of solute transport through hydrophilic dialysis membranes of regenerated cellulose that strongly put restrictions on the movement of water in the membrane was different from that through hydrophobic dialysis membranes. Analysis of the intramembrane diffusivity of the regenerated cellulose membrane based on the free volume theory revealed that the solute diffusivity was dependent on water content.
  • FUKUDA M; KANAMORI T; SAKAI K
    Jinko Zoki 一般社団法人 日本人工臓器学会 22 (1) 47 - 52 0300-0818 1993 [Refereed]
     
    Complement activation is reduced by grafting polyethylene glycol (PEG) on the surface of conventional regenerated cellulose (RC) membranes. However, the solute permeability of PEG-grafted RC membranes may be lower than that of conventional RC membranes because of the presence of swollen-layers formed with PEG chains on the PEG-grafted RC membranes. The objective of the present study is to clarify the difference in membrane structure between conventional RC (AM-SD) and PEG-grafted RC (AM-PC) membranes, and to characterize three PEG-grafted cellulosic membranes (AM-PC(l), PC(m), PC(s)) with varying PEG chain lengths based on the tortuous capillary pore model using data on tritium-labeled water (HTO) permeability and filtration coefficient.<br>The pore radius and surface porosity of the AM-SD, PC (m) and PC (s) membranes were calculated to be 2.8nm and 35%, respectively. On the other hand, the pore radius and surface porosity of the PC(l) membrane grafted with the longest PEG chains were lower than those of the conventional RC membrane (SD). This indicates that the pores of the PC (l) membrane are partially covered with the PEG chains.
  • FUKUDA MAKOTO; AWAKA TOORU; KANAMORI TOSHIYUKI; SAKAI KIYOTAKA
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 21 (3) 861 - 866 0300-0818 1992/06 [Refereed]
     
    Solute permeability is available using Wilson-Plot Method, Klein's Method, RI Method with radioisotope-labeled solute and a new method with optical fibers. Each method gives different values for solute permeability of same membranes, and little is known real values for solute permeability. This paper describes characteristics of methods of measuring solute permeability, and effects of membrane structure on solute permeability of highly permeable (HP) dialysis membranes.
    Real values for solute permeability of hollow-fiber dialysis membranes can be measured by a new method with optical fibers. Structural parameters of pore radius, surface porosity and tortuosity were determined for HP membranes from pure water permeability, solute permeability and water content data using the tortuous pore model. PAN-DX membrane has higher solute permeability than AM-EP membrane for substances of molecular weight ranging from 6, 000 to 20, 000, because PAN-DX membrane has huge pores.
  • Kanamori Toshiyuki; Fukuda Makoto; Sakai Kiyotaka
    MEMBRANE 日本膜学会 17 (1) 19 - 26 0385-1036 1992 [Refereed]
     
    A few highly permeable dialysis membranes have been developed so far to remove beta-2-microglobulin having a molecular weight of 11, 800 that was identified as a new form of amyloid protein from patients on long-term hemodialysis. The present study is to evaluate the solute permeability for low molecular weight proteins such as beta-2-microglobulin of the highly permeable dialysis membranes by varying technical methods.<BR>The membranes tested included conventional and highly permeable dialysis membranes made of regenerated cellulose, and also highly permeable dialysis membranes of polysulfone and polyacrylonitrile as a reference. Solute permeability was determined by 1) the Wilson-plot method, 2) the microanalysis method with radioisotope-labeled solutes and 3) the photometric measurement. Test solutes were vitamin B<SUB>12</SUB> beta-2-microglobulin, cytochrome-C and myoglobin.<BR>The highly permeable dialysis membranes of regenerated cellulose had higher surface porosities and pore sizes calculated from solute and pure water permeabilities and water content data that were practically the same as synthetic polymer membranes. This demonstrates that advanced membrane preparation techniques are capable of forming great surface porosity and large pore size on regenerated cellulose dialysis membranes.<BR>The Wilson-plot method is incapable of determination of diffusive permeability without ultrafiltration. Continuous measurements of optical density of a test solution in a hollow with optical fibers are well suited for precise determination of solute permeability by diffusion.<BR>The removed amount of beta-2-microglobulin calculated from solute permeability data of the most highly permeable dialysis membranes may not exceed the generated amount of beta-2-microglobulin.
  • AOKI Y; AWAKA T; FUKUDA M; KANAMORI T; SAKAI K; NISHIKIDO J; WATANABE T; FUSHIMI F
    Jinko Zoki 一般社団法人 日本人工臓器学会 21 (3) 982 - 986 0300-0818 1992 [Refereed]
     
    Highly permeable (HP) membranes have higher solute permeabilities than conventional ones. Contribution of blood- and dialysate-side mass transfer resistances to solute removal performance is more increased in HP dialyzers than conventional ones. To reduce blood- and dialysate-side mass transfer resistances effectively increases solute removal performance especially of HP dialyzers. This paper describes the technical design of dialyzers with being reduced blood-side mass transfer resistance. Dialyzers consisting of hollow-fiber membranes of 19.4cm in length was superior in solute removal perormance to dialyzers consisting of hollow-fiber membranes of 23.5cm in length. Overall mass transfer coefficient and blood-side mass transfer coefficient were independent of blood-side flow rate. Overall mass transfer coefficient was independent of inner diameter of hollow fibers.
  • FUKUDA M; AWAKA T; KANAMORI T; SAKAI K
    Jinko Zoki 一般社団法人 日本人工臓器学会 21 (3) 861 - 866 0300-0818 1992 [Refereed]
     
    Solute permeability is available using Wilson-Plot Method, Klein's Method, RI Method with radioisotope-labeled solute and a new method with optical fibers. Each method gives different values for solute permeability of same membranes, and little is known real values for solute permeability. This paper describes characteristics of methods of measuring solute permeability, and effects of membrane structure on solute permeability of highly permeable (HP) dialysis membranes.<br>Real values for solute permeability of hollow-fiber dialysis membranes can be measured by a new method with optical fibers. Structural parameters of pore radius, surface porosity and tortuosity were determined for HP membranes from pure water permeability, solute permeability and water content data using the tortuous pore model. PAN-DX membrane has higher solute permeability than AM-EP membrane for substances of molecular weight ranging from 6, 000 to 20, 000, because PAN-DX membrane has huge pores.
  • AWAKA T; FUKUDA M; AOKI Y; NAITO A; KANAMORI T; SAKAI K
    Jinko Zoki 一般社団法人 日本人工臓器学会 21 (3) 873 - 876 0300-0818 1992 [Refereed]
     
    Relationship between mass transfer and flow patttern in dialyzers is very important for optimal design of dialyzers. Mass transfer in dialysate-side is extremely complex to understand due to complexity of flow pattern. In this work, the basic analysis about mass transfer of dialysate was performed with single follow fiber membrane, which is considered as a simplest laminar flow condition. The experiment was carried out by the new method with optical fibers. The unsteady mass transfer model in a capillary membrane was applied to the new calculation method for the mass transfer coefficient of outside film of the hollow fiber membrane. AM-SD-10M which is conventional membrane and AM-FP-15 which is highly permeaole membrane were used in the experiment. No matter which membrane was concerned, mass transfer resistances of outside film were equal. Sherwood number measured experimentally fitted in with the Leveque's equation which was led by the theoretical analysis of heat transfer in laminar flow.
  • FUKUDA MAKOTO; KANAMORI TOSHIYUKI; SAKAI KIYOTAKA
    人工臓器(日本人工臓器学会) JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 22 (1) 47 - 52 0300-0818 1992 [Refereed]
     
    Complement activation is reduced by grafting polyethylene glycol (PEG) on the surface of conventional regenerated cellulose (RC) membranes. However, the solute permeability of PEG-grafted RC membranes may be lower than that of conventional RC membranes because of the presence of swollen-layers formed with PEG chains on the PEG-grafted RC membranes. The objective of the present study is to clarify the difference in membrane structure between conventional RC (AM-SD) and PEG-grafted RC (AM-PC) membranes, and to characterize three PEG-grafted cellulosic membranes (AM-PC(l), PC(m), PC(s)) with varying PEG chain lengths based on the tortuous capillary pore model using data on tritium-labeled water (HTO) permeability and filtration coefficient.
    The pore radius and surface porosity of the AM-SD, PC (m) and PC (s) membranes were calculated to be 2.8nm and 35%, respectively. On the other hand, the pore radius and surface porosity of the PC(l) membrane grafted with the longest PEG chains were lower than those of the conventional RC membrane (SD). This indicates that the pores of the PC (l) membrane are partially covered with the PEG chains.
  • FUKUDA M.
    Artif. Organs Today 2 205 - 214 1992 [Refereed]
  • FUKUDA M; HOSOYA N; KANAMORI T; SAKAI K; NISHIKIDO J; WATANABE T; FUSHIMI F
    Jinko Zoki 一般社団法人 日本人工臓器学会 20 (1) 59 - 64 0300-0818 1991 [Refereed]
     
    Highly permeable (HP) membranes have higher solute permeabilities than conventional ones. As a result, the contribution of dialysate film mass transfer resistance increased on HP dialyzers. It should be reduced to improve the mass transfer performance of HP dialyzers. Little is known concerning the technical design of dialyzers, considering dialysate film mass transfer resistance. This paper describes the technical design of dialyzers to reduce the dialysate film mass transfer resistance. The dialysate film mass transfer coefficient increased with the fiber density. The increase in fiber density increased the mass transfer rate of HP dialyzers more effectively than that of conventional dialyzers. Keller's equation, commonly used for the technical design of dialyzers, should be modified because the dialysate film mass transfer coefficient calculated from the equation did not agree with those determined by a dialysis experiment.

MISC

  • 重症呼吸不全に対するECMO治療戦略Up-to-Date 膜工学から見た体外式膜型人工肺(ECMO) ガス交換膜の進化と今後の展望
    福田 誠; 酒井 清孝  人工臓器  52-  (2)  S  -55  2023/10
  • CART用腹水濾過膜および濃縮膜の異方的細孔構造と蛋白質回収率の関係
    福田 誠; 芳谷 大輝; 島田 七海; 定野 和憲; 酒井 清孝; 森 智博; 竿本 仁志  人工臓器  52-  (2)  S  -131  2023/10
  • 走査型プローブ顕微鏡による血液濾過膜のファウリング前後の膜内表面形態解析
    福田 誠; 定野 和憲; 大森 結友; 酒井 清孝; 森 智博; 竿本 仁志  人工臓器  52-  (2)  S  -132  2023/10
  • 本邦初の2週間使用が認可されたECMO用ガス交換膜の膜構造解析
    定野 和憲; 福田 誠; 新垣 佑陽; 土肥 明香; 酒井 清孝; 竿本 仁志; 齋藤 茜; 森 岳志  人工臓器  51-  (2)  S  -155  2022/10
  • 2種類のTerumo Capioxガス交換膜の細孔構造とSARS-CoV-2透過リスクの検証
    福田 誠; 定野 和憲; 田中 涼; 酒井 清孝; 竿本 仁志; 森 智博; 河村 誠司  人工臓器  51-  (2)  S  -199  2022/10
  • Impact of three-dimensional tortuous pore structure on polyethersulfone membrane morphology and mass transfer properties from a manufacturing perspective(和訳中)
    Fukuda Makoto; Saomoto Hitoshi; Yoshimoto Hiroki; Kusumi Rei; Sakai Kiyotaka  人工臓器  48-  (2)  S  -137  2019/10
  • 走査型プローブ顕微鏡(SPM)による血液透析膜の3次元迷宮細孔構造解析
    福田 誠; 楠美 黎; 竿本 仁志; 酒井 清孝  人工臓器  48-  (2)  S  -120  2019/10
  • 走査型プローブ顕微鏡(SPM)による血液濃縮膜の血液接触前後の3次元迷宮細孔構造解析
    福田 誠; 吉本 拓記; 竿本 仁志; 酒井 清孝  人工臓器  48-  (2)  S  -194  2019/10
  • 福田誠; 竿本仁志; 酒井清孝  医工学治療  31-  (Supplement)  66  2019
  • 福田誠; 冷水大晟; 竿本仁志; 酒井清孝  人工臓器(日本人工臓器学会)  47-  (2)  S.83  2018/10
  • 福田誠; 青松真人; 荻野紗英; 酒井清孝  人工臓器(日本人工臓器学会)  47-  (2)  S.109  2018/10
  • 福田誠; 式田直生; 徳嶺朝子; 徳本真一; 和泉亮平; 迫田亨  人工臓器(日本人工臓器学会)  46-  (2)  S.98  2017/08
  • 福田誠; 櫻井幸尚; 小林昌平  人工臓器(日本人工臓器学会)  46-  (2)  S.149  2017/08
  • 福田誠; 小林昌平  日本透析医学会雑誌  50-  (Supplement 1)  588  2017/05
  • 福田誠; 小林昌平; 滑川亘希  人工臓器(日本人工臓器学会)  45-  (2)  S.111  2016/10
  • 福田誠; 森本柾允; 徳嶺朝子; 滑川亘希  人工臓器(日本人工臓器学会)  45-  (2)  S.136  2016/10
  • 福田誠; 古薗勉  日本透析医学会雑誌  48-  (Supplement 1)  391  2015/05
  • 福田誠; 秦弘樹; 西手芳明  日本血液浄化技術学会雑誌  23-  (1)  104  2015/04
  • 福田誠; 山本和輝; 萱島道徳  日本血液浄化技術学会雑誌  23-  (1)  108  2015/04
  • 福田誠  臨床透析  30-  (14)  1857  -1861  2014/12
  • 新しい親水化剤を用いたポリスルホン膜ダイアライザと従来ダイアライザとのPVP溶出特性の比較
    小村 真未; 中川 裕規; 山本 和輝; 前田 圭介; 福田 誠  Clinical Engineering  24-  (6)  606  -612  2013/05
  • 福田 誠  日本血液浄化技術学会会誌  20-  (1)  73  -73  2012/04
  • Fukuda Makoto  MEMBRANE  37-  (1)  10  -16  2012
  • 【透析のすべて-原理・技術・臨床-】透析膜
    福田 誠  Clinical Engineering  別冊-  (透析のすべて 原理・技術・臨床)  43  -48  2011/06
  • 積層型透析器の透析液流動と除去性能
    滑川 亘希; 上野 正高; 平野 彩香; 福田 誠; 酒井 清孝  医工学治療  23-  (Suppl.)  135  -135  2011/04
  • 透析膜内表面へのずり応力負荷とPVP溶出
    滑川 亘希; 金子 亜美; 松田 雅人; 岸川 竜也; 福田 誠; 酒井 清孝  医工学治療  23-  (Suppl.)  145  -145  2011/04
  • 川口正晃; 滑川亘希; 松田雅人; 福田誠; 酒井清孝  人工臓器(日本人工臓器学会)  39-  (2)  S92  -S92  2010/11
  • 上野正高; 滑川亘希; 福田誠; 酒井清孝; 平野彩香  人工臓器(日本人工臓器学会)  39-  (2)  S.92  2010/11
  • 【血液透析効率の評価法について再考する】各種性能指標の基礎と最近の問題点 ダイアライザの性能評価式(K、KoA)
    福田 誠  臨床透析  26-  (4)  399  -405  2010/04
  • 広範囲分子量におけるPVP溶出の定量的評価
    金子 亜美; 滑川 亘希; 青松 香里; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  医工学治療  22-  (Suppl.)  104  -104  2010/04
  • 滑川 亘希; 金子 亜美; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  日本血液浄化技術学会会誌  18-  (1)  54  -54  2010/04
  • 【ハイパフォーマンスメンブレン2009】基礎研究 PVP配合率の異なるPEPA膜からのPVP溶出特性
    青松 香里; 滑川 亘希; 八木 優; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  腎と透析  67-  (別冊 ハイパフォーマンスメンブレン'09)  121  -126  2009/10
  • 【ハイパフォーマンスメンブレン2009】基礎研究 EVAL透析膜とPVP配合合成高分子膜のHSA吸着力の比較
    滑川 亘希; 八木 優; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  腎と透析  67-  (別冊 ハイパフォーマンスメンブレン'09)  127  -131  2009/10
  • 【ハイパフォーマンスメンブレン2009】HDF・その他 血液透析濾過(HDF)透析器の設計に関する基礎的検討
    松石 健太郎; 八木 優; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  腎と透析  67-  (別冊 ハイパフォーマンスメンブレン'09)  149  -152  2009/10
  • 滑川亘希; 金子亜美; 青松香里; 松田雅人; 山本健一郎; 福田誠; 酒井清孝  人工臓器(日本人工臓器学会)  38-  (2)  S  -113  2009/10
  • 岸川竜也; 松田雅人; 滑川亘希; 山本健一郎; 薬師寺大二; 福田誠; 酒井清孝  人工臓器(日本人工臓器学会)  38-  (2)  S  -113  2009/10
  • 過剰なγ線照射が湿潤透析膜表面特性に与える影響
    松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 酒井 清孝  日本透析医学会雑誌  42-  (Suppl.1)  671  -671  2009/05
  • 透析膜のPVP溶出特性
    滑川 亘希; 青松 香里; 八木 優; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  日本透析医学会雑誌  42-  (Suppl.1)  720  -720  2009/05
  • 岸川竜也; 朝妻恵一; 松田雅人; 酒井清孝; 山本健一郎; 薬師寺大二; 福田誠  日本膜学会年会講演要旨集  31st-  2009
  • 岸川 竜也; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 酒井 清孝  化学工学会 研究発表講演要旨集  2009-  (0)  1031  -1031  2009
  • 滑川 亘希; 青松 香里; 松田 雅人; 山本 健一郎; 福田 誠; 酒井 清孝  化学工学会 研究発表講演要旨集  2009-  (0)  1032  -1032  2009
  • 國方 賢; 福田 誠; 山本 健一郎; 八木 優; 松田 雅人; 酒井 清孝  化学工学会 研究発表講演要旨集  2009-  (0)  695  -695  2009
  • 滑川 亘希; 福田 誠; 八木 優; 松田 雅人; 山本 健一郎; 酒井 清孝  化学工学会 研究発表講演要旨集  2009-  (0)  732  -732  2009
  • 【血液浄化膜の新しい展開】湿潤透析膜内表面特性のナノレベル評価の必要性
    松田 雅人; 朝妻 恵一; 阪田 宏樹; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  医工学治療  20-  (4)  246  -250  2008/12
  • 【HDF療法'08 HDF療法これまでの軌跡これからの展望】膜性能評価 内部濾過促進型ダイアライザAPS-15EXとAPS-15E on-line HDFの性能比較
    佐藤 和弘; 楢村 友隆; 井出 孝夫; 福田 誠; 薬師寺 大二; 宮坂 武寛  腎と透析  65-  (別冊 HDF療法'08)  229  -234  2008/11
  • 八木優; 滑川亘希; 國方賢; 松田雅人; 山本健一郎; 福田誠; 酒井清孝  人工臓器(日本人工臓器学会)  37-  (2)  S  -157  2008/11
  • 青松香里; 滑川亘希; 八木優; 松田雅人; 山本健一郎; 福田誠; 酒井清孝  人工臓器(日本人工臓器学会)  37-  (2)  S  -158  2008/11
  • 【ハイパフォーマンスメンブレン2008】アルブミン漏出を再考する 膜構造制御によるアルブミン漏出の抑制
    松田 雅人; 久保 宜昭; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  26  -29  2008/10
  • 【ハイパフォーマンスメンブレン2008】コンピュータシミュレーションによる透析器のハウジング形状が透析液流動に及ぼす影響の解析
    滝沢 夏生; 山本 健一郎; 松田 雅人; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  42  -46  2008/10
  • 【ハイパフォーマンスメンブレン2008】新型血液透析器における透析液側流動の無次元相関式による評価
    國方 賢; 八木 優; 松田 雅人; 山本 健一郎; 福田 誠; 薬師寺 大二; 宮坂 武寛; 酒井 清孝  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  47  -50  2008/10
  • 【ハイパフォーマンスメンブレン2008】最新の合成高分子系血液透析膜の内表面特性評価
    滑川 亘希; 八木 優; 松田 雅人; 山本 健一郎; 福田 誠; 薬師寺 大二; 宮坂 武寛; 酒井 清孝  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  51  -55  2008/10
  • 【ハイパフォーマンスメンブレン2008】透析膜表面PVP減少が表面特性に与える影響
    松田 雅人; 朝妻 恵一; 阪田 宏樹; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  56  -59  2008/10
  • 【ハイパフォーマンスメンブレン2008】透析膜へのずり応力負荷が親水化剤溶出および表面構造に与える影響
    朝妻 恵一; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  60  -63  2008/10
  • 【ハイパフォーマンスメンブレン2008】原子間力顕微鏡による血液透析膜の生体適合性の評価
    八木 優; 松田 雅人; 滑川 亘希; 國方 賢; 山本 健一郎; 酒井 清孝; 福田 誠; 薬師寺 大二; 宮坂 武寛  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン'08)  64  -67  2008/10
  • K. Yamamoto; N. Takizawa; M. Matsuda; T. Yakushiji; M. Fukuda; T. Miyasaka; K. Sakai  INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS  31-  (7)  642  -643  2008/07
  • 透析膜の生体適合性を示す指標としてのHSA吸着力
    八木 優; 滑川 亘希; 國方 賢; 松田 雅人; 山本 健一郎; 福田 誠; 薬師寺 大二; 宮坂 武寛; 酒井 清孝  日本透析医学会雑誌  41-  (Suppl.1)  569  -569  2008/05
  • タンパク質吸着に伴う透析膜表面構造変化が濾過係数に及ぼす影響
    松田 雅人; 島崎 裕史; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  日本透析医学会雑誌  41-  (Suppl.1)  748  -748  2008/05
  • 新しい人工腎臓の血液透析膜に対するHSA吸着力の評価
    八木 優; 松田 雅人; 滑川 亘希; 國方 賢; 山本 健一郎; 酒井 清孝; 福田 誠; 薬師寺 大二; 宮坂 武寛  医工学治療  20-  (Suppl.)  165  -165  2008/04
  • 透析膜内表面からのPVP溶出
    阪田 宏樹; 松川 裕章; 松田 雅人; 薬師寺 大二; 福田 誠; 宮坂 武寛; 山本 健一郎; 酒井 清孝  医工学治療  20-  (Suppl.)  166  -166  2008/04
  • 臨床工学技士に薦める今月の一冊 「バイオサイエンスの統計学 ―正しく活用するための実践理論―」
    福田誠  Clinical Engineering  16-  (5)  565  2008
  • 松田雅人; 島崎裕史; 山本健一郎; 薬師寺大二; 福田誠; 宮坂武寛; 酒井清孝  日本膜学会年会講演要旨集  30th-  2008
  • 久保宜昭; 松田雅人; 山本健一郎; 薬師寺大二; 福田誠; 宮坂武寛; 酒井清孝  化学工学会秋季大会研究発表講演要旨集(CD-ROM)  40th-  2008
  • 内部濾過促進型ダイアライザAPS-15EXと他のV型ダイアライザを用いたon-line HDFとの性能比較
    佐藤和弘; 楢村友隆; 井出孝夫; 福田誠; 薬師寺大二; 宮坂武寛  腎と透析  65-  (別冊 ハイパフォーマンスメンブレン’08)  163  -167  2008
  • 久保 宜昭; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2008-  (0)  1019  -1019  2008
  • 石田 幸成; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2008-  (0)  1096  -1096  2008
  • 久保 宜昭; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2008-  (0)  1158  -1158  2008
  • 石田 幸成; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2008-  (0)  957  -957  2008
  • 血液流動ストレスに対するポリスルホン膜内表面の親水化剤耐溶出性
    佐藤 美佳; 小川 貴久; 松田 雅人; 薬師寺 大二; 福田 誠; 宮坂 武寛; 山本 健一郎; 酒井 清孝  腎と透析  63-  (別冊 ハイパフォーマンスメンブレン'07)  66  -68  2007/11
  • 新型透析器のパルスレスポンス法と局所圧力測定による透析液流動評価
    長谷川 真衣; 山本 健一郎; 酒井 清孝; 薬師寺 大二; 福田 誠; 宮坂 武寛  腎と透析  63-  (別冊 ハイパフォーマンスメンブレン'07)  62  -65  2007/11
  • APS-DRY膜の表面キャラクタリゼーション
    松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 小泉 智徳; 吉田 一; 酒井 清孝  腎と透析  63-  (別冊 ハイパフォーマンスメンブレン'07)  44  -46  2007/11
  • 血液中のNOをモニタリングできる新しいシステムの開発
    松川 裕章; 奥岡 眞視; 松田 雅人; 薬師寺 大二; 福田 誠; 宮坂 武寛; 山本 健一郎; 酒井 清孝  腎と透析  63-  (別冊 ハイパフォーマンスメンブレン'07)  38  -40  2007/11
  • アルブミン漏出を抑制する非対称膜の設計
    南 めぐみ; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  腎と透析  63-  (別冊 ハイパフォーマンスメンブレン'07)  41  -43  2007/11
  • 滑川亘希; 八木優; 松田雅人; 福田誠; 薬師寺大二; 宮坂武寛; 酒井清孝  人工臓器(日本人工臓器学会)  36-  (2)  S48  -S48  2007/10
  • 阪田宏樹; 松田雅人; 薬師寺大二; 福田誠; 宮阪武寛; 山本健一郎; 酒井清孝  人工臓器(日本人工臓器学会)  36-  (2)  S47  -S47  2007/10
  • M. Matsuda; K. Yamamoto; T. Yakushiji; M. Fukuda; T. Miyasaka; K. Sakai  INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS  30-  (8)  721  -721  2007/08
  • PVP配合が湿潤PSフィルム表面特性に与える影響
    松田 雅人; 山本 健一郎; 福田 誠; 宮坂 武寛; 薬師寺 大二; 酒井 清孝  医工学治療  19-  (Suppl.)  112  -112  2007/02
  • 透析器軸方向および断面方向の親水化剤耐溶出性
    佐藤 美佳; 松田 雅人; 山本 健一郎; 福田 誠; 宮坂 武寛; 薬師寺 大二; 酒井 清孝  医工学治療  19-  (Suppl.)  112  -112  2007/02
  • 透析時血中NO濃度の新規モニタリングシステム開発
    松川 裕章; 松田 雅人; 山本 健一郎; 福田 誠; 宮坂 武寛; 薬師寺 大二; 酒井 清孝  医工学治療  19-  (Suppl.)  133  -133  2007/02
  • 松田雅人; 山本健一郎; 酒井清孝; 薬師寺大二; 福田誠; 宮坂武寛  日本膜学会年会講演要旨集  29th-  2007
  • 松田雅人; 小川貴久; 山本健一郎; 酒井清孝; 薬師寺大二; 福田誠; 宮坂武寛  日本膜学会年会講演要旨集  29th-  2007
  • 山本健一郎; 松田雅人; 酒井清孝; 薬師寺大二; 福田誠; 宮坂武寛  日本膜学会年会講演要旨集  29th-  2007
  • 土井 貴彦; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2007-  (0)  866  -866  2007
  • 松川 裕章; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2007-  (0)  869  -869  2007
  • 島崎 裕史; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2007-  (0)  870  -870  2007
  • 土井 貴彦; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2007-  (0)  967  -967  2007
  • 松川 裕章; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2007-  (0)  970  -970  2007
  • 島崎 裕史; 松田 雅人; 山本 健一郎; 薬師寺 大二; 福田 誠; 宮坂 武寛; 酒井 清孝  化学工学会 研究発表講演要旨集  2007-  (0)  971  -971  2007
  • 【ハイパフォーマンスメンブレン2006】基礎・開発 コンピュータシミュレーションによる高性能透析器の性能評価
    岩島 重人; 浅野 修司; 小堀 深; 酒井 清孝; 福田 誠; 日吉 辰夫  腎と透析  61-  (別冊 ハイパフォーマンスメンブレン'06)  119  -121  2006/11
  • 【ハイパフォーマンスメンブレン2006】基礎・開発 JMS全自動透析用コンソールを用いた透析モードの違いによる内部濾過促進型ダイアライザの物質除去量の検討
    宮崎 美和; 福田 誠; 上住 敏士; 吉田 一; 高橋 卓; 渡邉 哲夫; 正岡 勝則; 山中 邦彦  腎と透析  61-  (別冊 ハイパフォーマンスメンブレン'06)  126  -132  2006/11
  • 【ハイパフォーマンスメンブレン2006】ハイパフォーマンス・メンブレンを再検証する QOLの向上をめざしたダイアライザ開発への取り組みと今後の展開
    福田 誠; 吉田 一  腎と透析  61-  (別冊 ハイパフォーマンスメンブレン'06)  12  -18  2006/11
  • 【HDF療法'06】人工腎臓 新しいAPSダイアライザー(APS-SAシリーズ)の設計
    福田 誠; 宮崎 美和; 上住 敏士; 吉田 一  腎と透析  61-  (別冊 HDF療法'06)  240  -247  2006/10
  • 八木優; 山本健一郎; 酒井清孝; 薬師寺大二; 福田誠; 宮坂武寛  人工臓器(日本人工臓器学会)  35-  (2)  S.143  2006/10
  • 福田誠; 小川一; 薬師寺大二; 宮坂武寛  人工臓器(日本人工臓器学会)  35-  (2)  S.174  2006/10
  • 山本健一郎; 酒井清孝; 松田雅人; 薬師寺大二; 福田誠; 宮坂武寛  人工臓器(日本人工臓器学会)  35-  (2)  S88  -S88  2006/10
  • 瀬山徹; 山本健一郎; 酒井清孝; 薬師寺大二; 福田誠; 宮坂武寛  人工臓器(日本人工臓器学会)  35-  (2)  S.142  2006/10
  • 松田雅人; 山本健一郎; 酒井清孝; 薬師寺大二; 福田誠; 宮坂武寛  人工臓器(日本人工臓器学会)  35-  (2)  S87  -S87  2006/10
  • 衣笠 えり子; 青山 真人; 福田 誠  人工臓器  35-  (2)  S173  -S174  2006
  • 山本健一郎; 薬師寺大二; 小堀深; 酒井清孝; 福田誠  人工臓器(日本人工臓器学会)  34-  (2)  S.189  -s189  2005/11
  • 福田誠  人工臓器(日本人工臓器学会)  34-  (2)  S  -189  2005/11
  • 【ハイパフォーマンスメンブレン'05】内部濾過促進型APSダイアライザの開発
    福田 誠; 上住 敏士; 日吉 辰夫; 内 幸彦; 藤村 崇保  腎と透析  59-  (別冊 ハイパフォーマンスメンブレン'05)  115  -119  2005/10
  • 【ハイパフォーマンスメンブレン'05】透析器の透析液流動状態評価 新しいAPS透析器と従来型透析器の比較
    山本 健一郎; 樋渡 道士; 小堀 深; 酒井 清孝; 福田 誠; 日吉 辰夫  腎と透析  59-  (別冊 ハイパフォーマンスメンブレン'05)  112  -114  2005/10
  • 【ハイパフォーマンスメンブレン'05】新しいAPSダイアライザー(APS-SAシリーズ)の設計と評価
    宮崎 美和; 福田 誠; 上住 敏士; 日吉 辰夫  腎と透析  59-  (別冊 ハイパフォーマンスメンブレン'05)  106  -111  2005/10
  • 【ハイパフォーマンスメンブレン'05】内部濾過促進型APSダイアライザーの性能評価 内部濾過に及ぼす影響因子の検討
    小野 信行; 佐藤 加奈; 後藤 至宏; 衛藤 由香; 後藤 綾香; 田邊 恵子; 原 賢策; 松山 和弘; 松山 家昌; 友 雅司; 福田 誠  腎と透析  59-  (別冊 ハイパフォーマンスメンブレン'05)  220  -225  2005/10
  • ビタミンE固定化透析膜のスーパーオキシド消去に対する有効性
    山本 健一郎; 小林 憲由; 小堀 深; 酒井 清孝; 松本 優; 福田 誠; 日吉 辰夫; 遠藤 恒介  医工学治療  17-  (Suppl.)  160  -160  2005/05
  • (特集 内部濾過促進型血液透析 ―新しい血液浄化療法としての可能性を考える―)内部濾過促進型ダイアライザの設計に関する基本的な考え方.
    福田誠  Clinical Engineering  16-  (10)  1025  -1032  2005
  • 山本 健一郎; 小林 憲由; 小堀 深; 酒井 清孝; 松本 優; 福田 誠; 日吉 辰夫; 遠藤 恒介  化学工学会 研究発表講演要旨集  2005-  (0)  291  -291  2005
  • 福田誠; 宮崎美和; 上住敏士; 日吉辰夫; 内幸彦; 藤村崇保  人工臓器(日本人工臓器学会)  33-  (3)  288  -290  2004/12
  • 【ハイパフォーマンスメンブレン2004】膜の性能評価 APS-15Eと,その中空糸充填率を増加させた試作品との血漿系透析実験における性能比較
    石森 勇; 佐藤 雄一; 金子 岩和; 峰島 三千男; 秋葉 隆; 福田 誠  腎と透析  57-  (別冊 ハイパフォーマンスメンブレン'04)  37  -40  2004/09
  • 【生体適合面からみた透析機器】生体適合性発現のメカニズム PS膜ダイアライザを例として
    葉山 順代; 酒井 清孝; 福田 誠; 日吉 辰夫  臨床透析  20-  (5)  517  -520  2004/05
  • 藤村崇保; 内幸彦; 福田誠; 宮崎美和; 上住敏士; 日吉辰夫  人工臓器(日本人工臓器学会)  32-  (2)  S.119  2003/09
  • 葉山順代; 山本健一郎; 小堀深; 酒井清孝; 福田誠; 日吉辰夫  人工臓器(日本人工臓器学会)  32-  (2)  S119  -S119  2003/09
  • ポリスルホン透析膜の優れた生体適合性発現のメカニズム
    葉山 順代; 山本 健一郎; 小堀 深; 福田 誠; 日吉 辰夫; 酒井 清孝  日本透析医学会雑誌  36-  (Suppl.1)  823  -823  2003/05
  • 葉山順代; 山本健一郎; 小堀深; 福田誠; 日吉辰夫; 酒井清孝  人工臓器(日本人工臓器学会)  31-  (2)  S138  -S138  2002/09
  • (特集 血液透析入門)ダイアライザの構造と機能
    福田誠  Clinical Engineering  13-  (4)  287  -292  2002
  • 【ハイパフォーマンスメンブレン'00】膜の性能評価(in vitro) 高性能透析器における至適中空糸内径の検討
    宮坂 武寛; 村尾 一樹; 中島 亜弓; 酒井 清孝; 福田 誠; 日吉 辰夫  腎と透析  49-  (別冊 ハイパフォーマンスメンブレン'00)  20  -23  2000/07
  • BIOREXR AM-BC-X膜の透析液汚染物質侵入抑制効果について
    佐藤良和; 鈴木隆慈; 伊東由紀枝; 河合華代; 酒井貞子; 田山宏典; 新倉一彦; 衣笠えり子; 秋澤忠男; 出浦照國; 福田誠; 日吉辰夫; 西田治; 渡邊哲夫  腎と透析  47-  (別冊)  38  -41  1999
  • 対称グラジエント孔構造を有するBIOREXR AM-BC-150Xの特徴研究
    岩本和子; 大塚孝幸; 小川一; 松山家久; 福田誠; 日吉辰夫; 西田治  腎と透析  47-  (別冊)  34  -37  1999
  • 中島 亜弓; 関口 浩二; 田山 宏典; 福田 誠; 川端 研治; 宮内 英征  人工臓器  28-  (4)  s39  -s42  1999
  • 透析膜の表面粗さが抗血栓性に及ぼす影響
    小久保謙一; 角田奈々絵; 酒井清孝; 福田誠; 宮崎誠; 日吉辰夫  腎と透析  52-  (別冊)  12  -14  1998
  • 福田誠; 宮崎誠; 日吉辰夫  セルロース学会年次大会講演要旨集  5th-  1998
  • 國友 哲之輔; 柴田 猛; 藤森 明; 小川 一; 福田 誠  人工臓器  27-  (4)  S93  -S94  1998
  • 透析液からエンドトキシンが流入しにくい非対称透析膜の構造
    小久保謙一; 大西豪; 酒井清孝; 福田誠; 日吉辰夫  腎と透析  51-  (別冊)  46  -49  1997
  • 阿岸 鉄三; 高島 征助; 金森 敏幸; 新保 外志夫; 酒井 清孝; 塚原 隆史; 小久保 謙一; 酒井 清孝; 大西 豪; 福田 誠; 宮崎 誠; 日吉 辰夫; 角田 奈々絵  人工臓器  26-  (0)  S69  -S71  1997
  • 天野 泉; 川村 明夫; 久木田 和丘; 玉置 透; 山岡 一平; 網屋 毅之; 山下 明泰; 崎山 亮一; 赤木 亮之; 鈴木 大; 飛田 美穂; 佐中 孜; 角田 隆俊; 藤崎 智隆; 武林 祥裕; 北村 真; 田中 進一; 星野 政陽; 細矢 範行; 佐々木 正富; 福田 誠; 宮崎 誠; 峰島 三千男; 日吉 辰夫; 上坂 正利; 薮下 肇; 松山 家久; 小川 一; 金子 岩和; 阿岸 鉄三; 天野 泉; 佐藤 元美; 森田 弘之; 米川 元樹  人工臓器  26-  (0)  S180  -S183  1997
  • ポリエチレングリコールをグラフトした再生セルロース膜の中空糸内流動状態と抗血栓性
    小久保謙一; 竹脇幸治; 酒井清孝; 福田誠; 日吉辰夫  腎と透析  50-  (別冊)  52  -55  1996
  • 金森 敏幸; 似鳥 嘉昭; 宮崎 哲夫; 内藤 秀宗; 藤森 明; 徳小田 康秀; 吾妻 眞幸; 橋本 幸枝; 上坂 正利; 小島 弘栄; 似鳥 嘉昭; 藤森 明; 宮崎 誠; 福田 誠; 日吉 辰夫; 大西 豪; 小久保 謙一; 酒井 清孝; 福田 誠; 日吉 辰夫; 内藤 秀宗; 宮崎 哲夫; 徳小田 康秀; 吾妻 眞幸; 橋本 幸枝; 上坂 正利; 小島 弘栄  人工臓器  25-  (0)  S119  -S121  1996
  • 金森敏幸; 酒井清孝; 福田誠  化学工学シンポジウムシリーズ  41-  1994
  • 福田 誠; 笠井 秀俊; 横木 正信; 山下 康彦; 宍戸 寛治  人工臓器  23-  (0)  S109a  -S109a  1994
  • AM-PC膜におけるPEG鎖長と溶質透過性の関係
    金森敏幸; 福田誠; 酒井清孝; 山下康彦  腎と透析  34-  (別冊)  48  -51  1993
  • 福田誠; 金森敏幸; 酒井清孝  化学工学会秋季大会研究発表講演要旨集  25th-  (Pt 3)  1992
  • 福田誠; 細矢範行; 金物敏幸; 酒井清孝; 錦戸条一; 渡辺哲夫; 伏見文良  化学工学会年会研究発表講演要旨集  56th-  1991
  • アルブミン漏出を抑制する非対称膜の構造.
    南めぐみ; 松田雅人; 山本健一郎; 薬師寺大二; 福田誠; 宮坂武寛; 酒井清孝  腎と透析63 (別冊) ハイパフォーマンスメンブレン’07  63-  31  -43

Books and other publications

Lectures, oral presentations, etc.

  • 福田誠; 竿本仁志; 酒井清孝
    医工学治療  2019
  • FUKUDA MAKOTO; FURUZONO TSUTOMU
    日本透析医学会雑誌  2015/05
  • (アルブミン漏出を再考する)膜構造制御によるアルブミン漏出の抑制.  [Invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • コンピュータシミュレーションによる透析器テーパ構造の至適設計.  [Not invited]
    日本透析医学会学術集会・総会(第53回)  2008
  • タンパク質吸着に伴う透析膜表面構造変化が濾過係数に及ぼす影響.  [Not invited]
    日本透析医学会学術集会・総会(第53回)  2008
  • 透析膜の生体適合性を示す指標としてのHAS吸着力.  [Not invited]
    日本透析医学会学術集会・総会(第53回)  2008
  • 小型O2-濃度測定装置の開発.  [Not invited]
    日本透析医学会学術集会・総会(第53回)  2008
  • ポリスルフォン膜ダイアライザを使用する症例において血小板活性化因と考えられる不具合への対応.  [Not invited]
    日本透析医学会学術集会・総会(第53回)  2008
  • ニプロ社製ダイアライザPES-210Sαに適したon-lineHDF条件の検討.  [Not invited]
    日本透析医学会学術集会・総会(第53回)  2008
  • 透析膜内表面からのPVP溶出.  [Not invited]
    日本医工学治療学会 第24回学術大会  2008
  • 新しい人工腎臓の血液透析膜に対するHSA吸着力の評価.  [Not invited]
    日本医工学治療学会 第24回学術大会  2008
  • 透析器ジャケットのテーパ形状が透析液流動に及ぼす影響.  [Not invited]
    日本医工学治療学会 第24回学術大会  2008
  • 無次元相関式を用いた血液透析器の透析液側流動状態の評価.  [Not invited]
    日本医工学治療学会 第24回学術大会  2008
  • 内部濾過促進型ダイアライザAPS-15EXと他のⅤ型ダイアライザを用いたon-lineHDFとの性能比較.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • ニプロ社製ダイアライザPES-210Sαに適したon-lineHDF条件の検討.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • 原子間力顕微鏡による血液透析膜の生体適合性の評価.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • 透析膜へのずり応力負荷が親水化剤溶出および表面構造に与える影響.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • 透析膜表面PVP減少が表面特性に与える影響.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • 最新の合成高分子系血液透析膜の内表面特性評価.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • 新型透析器における透析液側流動の無次元相関式による評価.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • 透析器ハウジング形状が透析液流動に及ぼす影響.  [Not invited]
    第23回ハイパフォーマンス・メンブレン研究会  2008
  • ドライタイプポリスルホン透析膜の内表面特性.  [Not invited]
    第45回日本人工臓器学会大会 第2回国際人工臓器学術大会  2007
  • 透析膜内表面PVPの溶出特性.  [Not invited]
    第45回日本人工臓器学会大会 第2回国際人工臓器学術大会  2007
  • タンパク質吸着が透析膜構造および透水性におよぼす影響.  [Not invited]
    化学工学会 第39回秋季大会  2007
  • 透析患者の血中NO濃度を測定する新規デバイスの開発.  [Not invited]
    化学工学会 第39回秋季大会  2007
  • 透析器における内部濾過が溶質除去特性に与える影響.  [Not invited]
    化学工学会 第39回秋季大会  2007
  • 内部濾過促進型ダイアライザAPS-15EXとAPS-15E on-lineHDFの性能比較  [Not invited]
    第13回日本HDF研究会  2007
  • ニプロ社製ダイアライザPES-210Sαに適したon-lineHDF条件の検討.  [Not invited]
    第13回日本HDF研究会  2007
  • Characterization of wet PS/PVP film surfaces by atomic force microscopy.  [Not invited]
    ESAO 2007 XXXIV Conference  2007
  • Visualization of blood flow in membrane oxygenator with varying number of outlet ports.  [Not invited]
    American Society for Artificial Internal Organs (ASAIO) 53rd Annual Conference  2007
  • Improved housing of a new dialyzer to optimize dialysate flow.  [Not invited]
    XLIV ERA-EDTA Congress / Barcelona  2007
  • 新しいモイスチャータイプダイアライザーCS-1.6Uの臨床評価.  [Not invited]
    日本透析医学会学術集会・総会(第52回)  2007
  • 原子間力顕微鏡を用いた湿潤透析膜表面特性の新規評価手法.  [Not invited]
    日本膜学会 第29回年会  2007
  • ずり応力に対する透析膜表面PVPの耐溶出性.  [Not invited]
    日本膜学会 第29年会  2007
  • ビタミンE固定化ポリスルホン膜の抗酸化能評価.  [Not invited]
    日本膜学会 第29年会  2007
  • 血液流動ストレスに対するポリスルホン膜内表面の親水化剤耐溶出性.  [Not invited]
    第22回ハイパフォーマンス・メンブレン研究会 (セッションⅠ 基礎Ⅱ 35.)  2007
  • 新型透析器のパルスレスポンス法と局所圧力測定による透析液流動評価.  [Not invited]
    第22回ハイパフォーマンス・メンブレン研究会 (セッションⅠ 基礎Ⅱ 34.)  2007
  • 新しいモイスチャータイプダイアライザーCS-1.6Uの臨床評価.  [Not invited]
    第22回ハイパフォーマンス・メンブレン研究会 (セッションⅣ 東レ:PS膜の評価 19.)  2007
  • APS-DRY膜の表面キャラクタリゼーション.  [Not invited]
    第22回ハイパフォーマンス・メンブレン研究会 (セッションⅠ 基礎Ⅰ 5.)  2007
  • アルブミン漏出を抑制する非対称膜の構造.  [Not invited]
    第22回ハイパフォーマンス・メンブレン研究会 (セッションⅠ 基礎Ⅰ 4.)  2007
  • 血液中のNOをモニタリングする新しいシステムの開発.  [Not invited]
    第22回ハイパフォーマンス・メンブレン研究会 (セッションⅠ 基礎Ⅰ 3.)  2007
  • 人工肺モジュールの血液側流動.  [Not invited]
    第9回化学工学会学生発表大会 (D 04)  2007
  • 透析器における拡散と濾過の役割.  [Not invited]
    日本医工学治療学会 第23回学術大会 (O 55)  2007
  • 透析時血中NO濃度の新規モニタリングシステム開発.  [Not invited]
    日本医工学治療学会 第23回学術大会 (O 49)  2007
  • コンピュータシミュレーションによる人工肺モジュールの設計.  [Not invited]
    日本医工学治療学会 第23回学術大会 (O30)  2007
  • 人工肺モジュールにおける血液側流動.  [Not invited]
    日本医工学治療学会 第23回学術大会 (O 28)  2007
  • 透析器軸方向および断面方向の親水化剤耐溶出性.  [Not invited]
    日本医工学治療学会 第23回学術大会 (O 8)  2007
  • PVP配合が湿潤PSフィルム表面特性に与える影響.  [Not invited]
    日本医工学治療学会 第23回学術大会 (O 7)  2007
  • 透析器の真のTMPの測定とUFRPの経時変化の検討.  [Not invited]
    日本人工臓器学会大会(第44回) (P36)  2006
  • 外部灌流膜型人工肺モジュール内の血液側流動.  [Not invited]
    日本人工臓器学会大会(第44回) (G 141)  2006
  • シミュレーション解析による人工肺の至適設計.  [Not invited]
    日本人工臓器学会大会(第44回) (G 140)  2006
  • ウェーブ状中空糸膜と新しいハウジングを用いた透析器の性能評価.  [Not invited]
    日本人工臓器学会大会(第44回) (G 034)  2006
  • PVP配合量およびγ線照射量が湿潤透析膜表面のタンパク質吸着特性に与える影響.  [Not invited]
    日本人工臓器学会大会(第44回) (G 031)  2006
  • ずり応力が透析膜の表面性状に与える影響.  [Not invited]
    化学工学会 第38回秋季大会 (Va 041)  2006
  • シミュレーション解析による人工肺の至適血液流動.  [Not invited]
    機能性材料を利用した新規デバイス・プロセスに関するシンポジウム (ポスター 30)  2006
  • 湿潤PSフィルム表面のポリビニルピロリドンによるタンパク質吸着抑制効果.  [Not invited]
    機能性材料を利用した新規デバイス・プロセスに関するシンポジウム (ポスター 22)  2006
  • Technical Evaluation of Dialysate Flow in Rexeed.  [Not invited]
    ASAIO's Anniversary Conference (52th)  2006
  • 透析液流れの3次元解析による高性能透析器の性能評価.  [Not invited]
    日本透析医学会学術集会・総会(第51回) (O141)  2006
  • APS-SA透析器の性能評価.  [Not invited]
    日本医工学治療学会 第22回学術大会 (一般演題12 63)  2006
  • JMS社全自動透析用コンソールを用いた、透析モードの違いによる内部ろ過促進型ダイアライザーの溶質除去量の検討.  [Not invited]
    第21回ハイパフォーマンス・メンブレン研究会 (Ⅲ 17 基礎・開発)  2006
  • コンピュータシミュレーションによる高性能透析器の性能評価.  [Not invited]
    第21回ハイパフォーマンス・メンブレン研究会 (Ⅲ 14 基礎・開発)  2006
  • QOLの向上を目指したダイアライザ開発と今後の展開.  [Not invited]
    第21回ハイパフォーマンス・メンブレン研究会 (ハイパフォーマンス・メンブレンを再検証する)  2006
  • 新しいAPSダイアライザー(APS-SA)の設計.  [Not invited]
    日本人工臓器学会大会(第43回)第11回HDF研究会 ジョイントセッション(J04)  2005
  • APS-SA透析器における透析液流動状態の評価.  [Not invited]
    日本人工臓器学会大会(第43回)第11回HDF研究会 ジョイントセッション(J03)  2005
  • Visualizang Dialysate Flow in Hemodialyzers Using MR Imaging.  [Not invited]
    American Society of Nephrology Reanal Week 2005 (TH-PO629)  2005
  • 内部濾過促進型ダイアライザの設計指針.  [Not invited]
    日本透析医学会学術集会・総会(第50回) (ワークショップ4 D-WS-4 血液浄化 ―治療法と浄化器の適正選択を考える―)  2005
  • ビタミンE固定化透析膜のスーパーオキシド消去に関する有効性.  [Not invited]
    日本医工学治療学会 第21回学術大会  2005
  • ビタミンE固定化透析膜のスーパーオキシド消去能.  [Not invited]
    化学工学会 70年会  2005
  • 透析器の透析液流動状態評価 -新しいAPS透析器と従来型透析器の比較-.  [Not invited]
    第20回ハイパフォーマンスメンブレン/次世代人工腎研究会 (膜の性能評価16)  2005
  • 内部ろ過促進型血液浄化器. ―開発のコンセプトとその可能性―  [Not invited]
    日本透析医学会学術集会・総会(第49回) (コンセンサスカンファレンス 血液浄化器の新分類 ~内部ろ過と透析液水質による再評価)  2004
  • 内部濾過促進型ダイアライザの開発.  [Not invited]
    日本人工臓器学会大会(第41回)(人工腎 )  2003
  • ポリスルホン透析膜のクッション効果による生体適合性向上.  [Not invited]
    日本人工臓器学会大会(第41回)(人工腎 97)  2003
  • "Cushion Effect" of polyvinylpirrolidone Polymer Particles Improves Biocompatibility of Polysulfone Dialysis Membranes.  [Not invited]
    ASAIO-ISAO Joint Conference  2003
  • Nanometer Size Polyvinylpirrolidone Polymer Particles Determine Biocompatibility of Polysulfone Dialysis Membrane.  [Not invited]
    World Congress of Nephrology 2003  2003
  • ポリスルホン透析膜の優れた生体適合性発現のメカニズム.  [Not invited]
    日本透析医学会学術集会・総会(第48回)  2003
  • 乾燥・湿潤による透析膜表面構造変化の観察.  [Not invited]
    日本人工臓器学会大会(第40回)(人工腎4 60)  2002

Affiliated academic society

  • JAPANESE SOCIETY FOR MEDICAL AND BIOLOGICAL ENGINEERING   化学工学会   日本医工学治療学会The Japanese Society for Therapeutics and Engineering   日本透析医学会   日本人工臓器学会JAPANESE SOCIETY FOR ARTIFICIAL ORGANS   日本膜学会The Membrane Society of Japan   一般社団法人日本臨床工学技士教育施設協議会Japan Association of Educational Facilities of Clinical Engineers   

Industrial Property Rights