TOKUMINE Asako

    Department of Biomedical Engineering Lecturer
Last Updated :2024/04/25

Researcher Information

URL

J-Global ID

Research Interests

  • 人工心肺   医学シミュレーション   体外循環教育   教育用シミュレータ   clinical engineering   medical engineering   

Research Areas

  • Life sciences / Medical systems

Academic & Professional Experience

  • 2016/04 - Today  Kindai UniversityFaculty of Biology-Oriented Science and Technology講師
  • 2012 - 2016/03  Kindai UniversityFaculty of Biology-Oriented Science and Technology助教

Published Papers

  • Makoto Fukuda; Ryo Tanaka; Kazunori Sadano; Asako Tokumine; Tomohiro Mori; Hitoshi Saomoto; Kiyotaka Sakai
    Membranes 12 (3) 2022/03 
    When using the extracorporeal capillary membrane oxygenator (sample A) for ECMO treatments of COVID-19 severely ill patients, which is dominantly used in Japan and worldwide, there is a concern about the risk of SARS-CoV-2 scattering from the gas outlet port of the membrane oxygenator. Terumo has launched two types of membranes (sample A and sample B), both of which are produced by the microphase separation processes using polymethylpentene (PMP) and polypropylene (PP), respectively. However, the pore structures of these membranes and the SARS-CoV-2 permeability through the membrane wall have not been clarified. In this study, we analyzed the pore structures of these gas exchange membranes using our previous approach and verified the SARS-CoV-2 permeation through the membrane wall. Both have the unique gradient and anisotropic pore structure which gradually become denser from the inside to the outside of the membrane wall, and the inner and outer surfaces of the membrane have completely different pore structures. The pore structure of sample A is also completely different from the other membrane made by the melt-extruded stretch process. From this, the pore structure of the ECMO membrane is controlled by designing various membrane-forming processes using the appropriate materials. In sample A, water vapor permeates through the coating layer on the outer surface, but no pores that allow SARS-CoV-2 to penetrate are observed. Therefore, it is unlikely that SARS-CoV-2 permeates through the membrane wall and scatter from sample A, raising the possibility of secondary ECMO infection. These results provide new insights into the evolution of a next-generation ECMO membrane.
  • Makoto Fukuda; Tomoya Furuya; Kazunori Sadano; Asako Tokumine; Tomohiro Mori; Hitoshi Saomoto; Kiyotaka Sakai
    Membranes 11 (7) 2021/07 
    The objective of this study is to clarify the pore structure of ECMO membranes by using our approach and theoretically validate the risk of SARS-CoV-2 permeation. There has not been any direct evidence for SARS-CoV-2 leakage through the membrane in ECMO support for critically ill COVID-19 patients. The precise pore structure of recent membranes was elucidated by direct microscopic observation for the first time. The three types of membranes, polypropylene, polypropylene coated with thin silicone layer, and polymethylpentene (PMP), have unique pore structures, and the pore structures on the inner and outer surfaces of the membranes are completely different anisotropic structures. From these data, the partition coefficients and intramembrane diffusion coefficients of SARS-CoV-2 were quantified using the membrane transport model. Therefore, SARS-CoV-2 may permeate the membrane wall with the plasma filtration flow or wet lung. The risk of SARS-CoV-2 permeation is completely different due to each anisotropic pore structure. We theoretically demonstrate that SARS-CoV-2 is highly likely to permeate the membrane transporting from the patient's blood to the gas side, and may diffuse from the gas side outlet port of ECMO leading to the extra-circulatory spread of the SARS-CoV-2 (ECMO infection). Development of a new generation of nanoscale membrane confirmation is proposed for next-generation extracorporeal membrane oxygenator and system with long-term durability is envisaged.
  • Makoto Fukuda; Asako Tokumine; Kyohei Noda; Kiyotaka Sakai
    Membranes 10 (11) 2020/11 
    This article developes a pediatric membrane oxygenator that is compact, high performance, and highly safe. This novel experimental approach, which imaging the inside of a membrane oxygenator during fluid perfusion using high-power X-ray CT, identifies air and blood retention in the local part of a membrane oxygenator. The cause of excessive pressure drop in a membrane oxygenator, which has been the most serious dysfunction in cardiovascular surgery and extracorporeal membrane oxygenation (ECMO), is the local retention of blood and air inside the oxygenator. Our designed blood flow channel for a membrane oxygenator has a circular channel and minimizes the boundary between laminated parts. The pressure drop in the blood flow channel is reduced, and the maximum gas transfer rates are increased by using this pediatric membrane oxygenator, as compared with the conventional oxygenator. Furthermore, it would be possible to reduce the incidents, which have occurred clinically, due to excessive pressure drop in the blood flow channel of the membrane oxygenator. The membrane oxygenator is said to be the "last stronghold" for patients with COVID-19 receiving ECMO treatment. Accordingly, the specification of our prototype is promising for low weight and pediatric patients.
  • 千原 直己; 西垣 孝行; 小山 和彦; 徳嶺 朝子
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 43 (3) 277 - 277 0912-2664 2016/09
  • 体外循環教育シミュレータの適用による定型シナリオの手技評価と臨床経験の関係
    岡西 潤; 寺本 佳弘; 二宮 伸治; 徳嶺 朝子
    日本医療教授システム学会総会プログラム・抄録集 日本医療教授システム学会 6回 48 - 48 2014/03
  • Asako Tokumine; Naoki Momose; Yasuko Tomizawa
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER JAPAN KK 16 (4) 417 - 424 1434-7229 2013/12 [Refereed]
     
    Medical simulators have mainly been used as educational tools. They have been used to train technicians and to educate potential users about safety. We combined software for hybrid-type extracorporeal circulation simulation (ECCSIM) with a CPB-Workshop console. We evaluated the performance of ECCSIM, including its accuracy and repeatability, during simulated ECC. We performed a detailed evaluation of the synchronization of the software with the console and the function of the built-in valves. An S-III heart-lung machine was used for the open circuit. It included a venous reservoir, an oxygenator (RX-25), and an arterial filter. The tubes for venous drainage and the arterial line were connected directly to the ports of the console. The ECCSIM recorded the liquid level of the reservoir continuously. The valve in the console controlled the pressure load of the arterial line. The software made any adjustments necessary to both arterial pressure load and the venous drainage flow volume. No external flowmeters were necessary during simulation. We found the CPB-Workshop to be convenient, reliable, and sufficiently exact. It can be used to validate procedures by monitoring the controls and responses by using a combination of qualitative measures.
  • 人工臓器をめぐるシミュレーション 体外循環教育用シミュレーションシステムの現状と日本発標準型仮想患者シミュレーションモデルの提案
    二宮 伸治; 戸梶 めぐみ; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 42 (2) S - 53 0300-0818 2013/09
  • 循環器領域の医工学 人工心肺運転訓練シミュレーション装置の開発
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 末田 泰二郎
    医工学治療 (NPO)日本医工学治療学会 25 (Suppl.) 173 - 173 1344-1221 2013/04
  • 手術室チームを対象とした体外循環クロストレーニングの試み シミュレータ教育における新しい手法
    濱口 淳; 二宮 伸治; 徳嶺 朝子; 黛 成彦; 黒崎 達也; 末田 泰二郎
    医療職の能力開発 日本医療教授システム学会 2 (1) 15 - 24 2013/04 
    【背景と目的】心臓外科手術の危機資源管理においてチーム医療の概念は重要である。今回、心臓外科手術チームメンバーに対し、体外循環を中心としたクロストレーニングを試み、参加者アンケートの分析結果から、シミュレータを用いたチームダイナミクス手法の導入による体外循環のクロストレーニングが、メンバー相互の本質的な理解の向上にもたらす効果を検討した。【結果】アンケート調査の結果、トレーニング参加者54人中51人がシミュレータによるクロストレーニングが業務に役立つと回答した。アンケートの記述内容を分析した結果、参加者が気づくクロストレーニングの効果が4つのラベル(1.メンバーの業務への意識・興味を持つ、2.コミュニケーションの重要さへの気づき、3.自らの役割への応用、4.基礎の学習・深まり)に分類できることが明らかになった。【考察と結論】チーム医療においては、各メンバーは対象の観察から直接得られる情報と、取り扱うシステムの知識、インタフェースの知識から得られる情報源を集約して状況認識するが、本研究の結果は、Endsleyが示した状況認識の情報源図に加えて、4つのベクトルの必要性を示している。本結果より、シミュレータを用いたクロストレーニング手法の業務における意思決定や状況判断のスキルアップに対する有用性が示唆された。(著者抄録)
  • Momose Naoki; Tokumine Asako; Iwamoto Norio; Okada Hitomi; Kusaura Rie; Kokubo Ryo; Umeda Chinori; Yasuda Toru; Hayasaka Hideyuki; Yamaguchi Atsushi
    Japanese Journal of Extra-Corporeal Technology The Japanese Society of Extra-Corporeal Technology in Medicine 40 (4) 469 - 477 0912-2664 2013 
    We designed and examined venous reservoir level automatically controlling systems for an open-fashion cardiopulmonary bypass(CPB)circuit(an open circuit level controller; OLC)and a closed-fashion CPB circuit(closed circuit level controller; CLC). The OLC system consists of a CPU(central processing unit)and a slender column inserted through the top of the venous reservoir for measuring hydrostatic pressure. The CPU analyzes the hydrostatic pressure in the column as a replacement for the venous blood level and regulates the blood pump speed in proportion to the change of the hydrostatic pressure. The CLC system consists of a commercially available level sensor, which is attached in the side wall of the venous reservoir for directly measuring the venous blood level, and a CPU regulating the blood pump speed for keeping the appropriate venous blood level.
    Using a mock circulation model, we confirmed the both systems could maintain an appropriate blood level in the venous reservoir and regulate blood pump speed, leading to guarantee easy and safe management of the cardiopulmonary bypass.
  • 徳嶺 朝子; 二宮 伸治
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 39 (3) 306 - 306 0912-2664 2012/09
  • 二宮 伸治; 戸梶 めぐみ; 徳嶺 朝子; 上口 晃生; 工藤 雅彰; 岡村 直哉; 黒崎 達也; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 39 (3) 363 - 363 0912-2664 2012/09
  • 戸梶 めぐみ; 二宮 伸治; 黒崎 達也; 徳嶺 朝子; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 39 (3) 364 - 364 0912-2664 2012/09
  • 心臓血管外科領域の医工連携 人工心肺シミュレータの臨床への応用
    黒崎 達也; 徳嶺 朝子; 二宮 伸治; 末田 泰二郎
    医工学治療 (NPO)日本医工学治療学会 24 (Suppl.) 69 - 69 1344-1221 2012/03
  • 人工心肺制御システム評価における体外循環シミュレータの活用
    徳嶺 朝子; 百瀬 直樹; 柳澤 充延; 二宮 伸治; 冨澤 康子
    人工臓器 (一社)日本人工臓器学会 40 (2) S111 - S111 0300-0818 2011/10
  • 医療機器使用時のクライシスチームトレーニング 体外循環技術教育用シミュレータECCSIMのPCRM教育への適用可能性
    二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 黒崎 達也
    臨床シミュレーション研究 日本臨床シミュレーション機構 1 (1) 41 - 41 2186-2893 2011/06
  • 体外循環教育用シミュレータECCSIMに内蔵する仮想患者モデルの構築
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    臨床シミュレーション研究 日本臨床シミュレーション機構 1 (1) 63 - 63 2186-2893 2011/06
  • 体外循環技術教育用シミュレータシステムの開発と応用
    徳嶺 朝子; 二宮 伸治
    臨床シミュレーション研究 日本臨床シミュレーション機構 1 (1) 64 - 64 2186-2893 2011/06
  • 生体工学技術による人工臓器評価 体外循環装置操作技能 チーム連携評価における仮想患者シミュレータの活用
    二宮 伸治; 戸梶 めぐみ; 原 和信; 岡村 直哉; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 39 (2) S57 - S57 0300-0818 2010/11
  • 二宮 伸治; 戸梶 めぐみ; 原 和信; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 37 (3) 257 - 257 0912-2664 2010/09
  • 戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 岡原 重幸; 高橋 暢; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 37 (3) 270 - 270 0912-2664 2010/09
  • 細木 政載; 二宮 伸治; 山本 卓也; 岡村 直哉; 戸梶 めぐみ; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 37 (3) 271 - 271 0912-2664 2010/09
  • 徳嶺 朝子; 二宮 伸治; 原 和信; 岡村 直哉; 戸梶 めぐみ; 黒崎 達也
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 37 (3) 271 - 271 0912-2664 2010/09
  • 岡村 直哉; 二宮 伸治; 細木 和憲; 上口 晃生; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 37 (3) 279 - 279 0912-2664 2010/09
  • Asako Tokumine; Shinji Ninomiya; Megumi Tokaji; Tatsuya Kurosaki; Yasuko Tomizawa
    Journal of Extra-Corporeal Technology 42 (2) 139 - 144 0022-1058 2010/06 [Refereed]
     
    Although serious accidents during extracorporeal circulation are infrequent, potential adverse events with both equipment and operation do still occur and require immediate and well-coordinated responses. Hence, perfusionists need to be well trained in both standard and emergency procedures, and this would be aided by the establishment of an official education and training curriculum. In particular, the establishment of a simulator-based educational program and corresponding evaluation methods will spur development of increasingly medical simulators. Extra-Corporeal Circulation SIMulator (ECCSIM-Lite) was used during repeated sessions of undergraduate students (n = 12) using a simple training scenario. Trainees aimed to maintain reservoir volume around a constant mean, and increase or decrease the arterial flow avoiding rapid variations, and their performance was monitored. Ability to prevent backflow was also recorded as a measure of accomplishment. Skills in performances were evaluated by using a scoring system based on task accomplishment. Accomplishment score was improved in all participants after 1 week of training. Accomplishment scores reflecting ability to maintain flow improved to an average of 78% in the third and final practice session backflow was prevented in 100% of cases. The average reservoir level maintenance score in the flow-up phase was 75%, in the flow-maintenance phase was 92%, and in the flow-down phase was 58%. During skill training, in which trainees learn methods of avoiding adverse events, the use of simulators combined with tractable skills scores can ease the transition from training session to clinical practice. Use of these training scenarios within a perfusion education system also has the advantage of providing an index of trainees' current proficiency and improvement by providing tractable skill scores. In conclusion, the use of ECCSIM-Lite simulations, together with evaluation of task accomplishment over repeated training sessions, is an effective method of basic skill training for perfusionists.
  • 体外循環領域で近未来に期待される治療 体外循環トレーニングのための仮想患者シミュレーションシステムの開発と効果
    二宮 伸治; 戸梶 めぐみ; 原 和信; 黒崎 達也; 徳嶺 朝子; 岡原 重幸; 高橋 秀暢; 末田 泰二郎
    医工学治療 (NPO)日本医工学治療学会 22 (Suppl.) 64 - 64 1344-1221 2010/04
  • 体外循環領域で近未来に期待される治療 心・血管制御機能を導入した仮想患者モデルによる高再現性体外循環シミュレータの可能性
    戸梶 めぐみ; 二宮 伸治; 黒崎 達也; 徳嶺 朝子; 岡原 重幸; 高橋 秀暢; 末田 泰二郎
    医工学治療 (NPO)日本医工学治療学会 22 (Suppl.) 65 - 65 1344-1221 2010/04
  • Shinji Ninomiya; Megumi Tokaji; Asako Tokumine; Tatsuya Kurosaki
    Journal of Extra-Corporeal Technology 41 (4) 206 - 212 0022-1058 2009/12 [Refereed]
     
    Perfusionists require a detailed understanding of a patient's physiological status while comprehending the mechanics and engineering of the cardiopulmonary bypass system, so it is beneficial for them to obtain relevant practical skills using extracorporeal circulation technology and educational physiological simulators. We designed a perfusion simulator system (ECCSIM: Extracorporeal Circulation SIMulator system) based on a hybrid of a simple hydraulic mock circulation loop linked to a computer simulation model. Patient physiological conditions (height, weight, and cardiac indices) were determined by a parameter estimation procedure and used to accurately reproduce hemodynamic conditions. Extracorporeal circulation trainees in pre-clinical education were able to maintain venous oxygen saturation levels above 50%, except during cardiac standstill and a brief resumption of pulsation. Infant amplitudes of reservoir volume oscillation and flow rate were greatly increased compared with adult cardiovascular parameters, this enabled the instructor to control the difficulty level of the operation using different hemodynamic variations. High-fidelity simula tor systems with controllable difficulty levels and high physiological reproducibility are useful in constructing a perfusion resource management environment that enable basic training and periodic crisis management drills to be performed.
  • 人工臓器で発生する血栓の監視と対策 人工臓器モデル内における血栓形成 血栓形成は予測できるのか?
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 38 (2) S - 54 0300-0818 2009/10
  • 人工臓器で発生する血栓の監視と対策 人工肺前後圧および流量測定による血液粘度モニタリング法の検討
    徳嶺 朝子; 二宮 伸治; 岡村 直哉; 大槻 真之; 岡原 重幸; 黒崎 達也
    人工臓器 (一社)日本人工臓器学会 38 (2) S - 54 0300-0818 2009/10
  • 心血管制御モデルを導入した体外循環シミュレータの有用性について
    二宮 伸治; 戸梶 めぐみ; 黒崎 達也; 徳嶺 朝子; 原 和信
    人工臓器 (一社)日本人工臓器学会 38 (2) S - 162 0300-0818 2009/10
  • 戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 36 (3) 282 - 282 0912-2664 2009/09
  • 二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 黒崎 達也
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 36 (3) 283 - 283 0912-2664 2009/09
  • 岡村 直哉; 徳嶺 朝子; 大槻 真之; 二宮 伸治; 岡原 重幸; 黒崎 達也
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 36 (3) 321 - 321 0912-2664 2009/09
  • 医療安全における臨床工学の役割 医療安全確保のための体外循環技術教育用シミュレータの開発と有用性
    二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 黒崎 達也
    生体医工学 (公社)日本生体医工学会 47 (3) 329 - 329 1347-443X 2009/06
  • 体外循環技術の定量評価はできるか? 臨床経験とシミュレータ課題達成度の関係について
    徳嶺 朝子; 二宮 伸治; 冨澤 康子
    生体医工学 (公社)日本生体医工学会 47 (3) 333 - 333 1347-443X 2009/06
  • Katsutoshi Sato; Kazumasa Orihashi; Tatsuya Kurosaki; Asako Tokumine; Shintaro Fukunaga; Shinji Ninomiya; Taijiro Sueda
    ARTIFICIAL ORGANS WILEY-BLACKWELL PUBLISHING, INC 33 (4) 352 - 359 0160-564X 2009/04 [Refereed]
     
    In order to develop a diaphragm-type ventricular assist device (VAD), we studied the flow field change following structural modifications. We devised a center flow-type pump by putting a small projection on the center of the housing and/or diaphragm to provide a center in the flow field, and examined the following four types of VADs: N type without a projection, D type with a projection on the diaphragm, H type with a projection on the housing, and DH type with projections on both the diaphragm and housing. Computational fluid dynamics (CFD) was used for flow simulation. Particle image velocimetry (PIV) was also used to verify the reliability of the CFD method and to determine how the flow field changes in the presence of a projection. The results of the PIV and CFD analyses were comparable. The placement of a projection on the housing was most effective in rectifying the flow field.
  • 人工透析技術トレーニングシミュレータのための仮想患者モデルの検討
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    人工臓器 (一社)日本人工臓器学会 37 (2) S - 116 0300-0818 2008/11
  • 体外循環教育用シミュレータの施設教育への導入と訓練効果の検討
    二宮 伸治; 黒崎 達也; 戸梶 めぐみ; 岡原 重幸; 高橋 秀暢; 徳嶺 朝子; 原 和信
    人工臓器 (一社)日本人工臓器学会 37 (2) S - 116 0300-0818 2008/11
  • 体外循環教育用シミュレータの動的応答の改善とその効果
    徳嶺 朝子; 越川 翠; 二宮 伸治
    人工臓器 (一社)日本人工臓器学会 37 (2) S - 117 0300-0818 2008/11
  • 拍動型人工心臓におけるポンプ内部の突起による内部流場の整流効果(CFD法とPIV法の比較)
    佐藤 克敏; 黒崎 達也; 渡橋 和政; 末田 泰二郎; 徳嶺 朝子; 二宮 伸治; 香口 真作
    人工臓器 (一社)日本人工臓器学会 37 (2) S - 146 0300-0818 2008/11
  • 人工臓器モデル内における血栓形成と微少圧変化
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 37 (2) S - 180 0300-0818 2008/11
  • 戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 35 (3) 292 - 292 0912-2664 2008/09
  • Yasuko Tomizawa; Asako Tokumine; Shinji Ninomiya; Naoki Momose; Toru Matayoshi
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER TOKYO 11 (3) 117 - 122 1434-7229 2008/09 [Refereed]
     
    The heart-lung machines for open-heart surgery have improved over the past 50 years; they rarely break down and are almost always equipped with backup batteries. The hand-cranking procedure only becomes necessary when a pump breaks down during perfusion or after the batteries have run out. In this study, the performance of hand cranking a roller pump was quantitatively assessed by an objective method using the ECCSIM-Lite educational simulator system. A roller pump connected to an extracorporeal circuit with an oxygenator and with gravity venous drainage was used. A flow sensor unit consisting of electromagnetic sensors was used to measure arterial and venous flow rates, and a built-in pressure sensor was used to measure the water level in the reservoir. A preliminary study of continuous cranking by a team of six people was conducted as a surprise drill. This system was then used at a perfusion seminar. At the seminar, 1-min hand-cranking drills were conducted by volunteers according to a prepared scenario. The data were calculated on site and trend graphs of individual performances were given to the participants as a handout. Preliminary studies showed that each person's performance was different. Results from 1-min drills showed that good performance was not related to the number of clinical cases experienced, years of practice, or experience in hand cranking. Hand cranking to maintain the target flow rate could be achieved without practice; however, manipulating the venous return clamp requires practice. While the necessity of performing hand cranking during perfusion due to pump failure is rare, we believe that it is beneficial for perfusionists and patients to include hand-cranking practice in periodic extracorporeal circulation crisis management drills because a drill allows perfusionists to mentally rehearse the procedures should such a crisis occur.
  • 人工心肺技術の教育 体外循環訓練シミュレータECCSIM-Liteのシナリオ作成と使用経験
    佐藤 美保子; 新 秀直; 久保 仁; 玉井 久義; 二宮 伸治; 徳嶺 朝子; 又吉 徹; 百瀬 直樹; 冨澤 康子
    人工臓器 (一社)日本人工臓器学会 36 (2) S58 - S58 0300-0818 2007/10
  • 人工心肺技術の教育 体外循環技術習得のための教育用シミュレータシステムの開発
    二宮 伸治; 徳嶺 朝子; 黒崎 達也; 福永 信太郎; 冨澤 康子
    人工臓器 (一社)日本人工臓器学会 36 (2) S58 - S58 0300-0818 2007/10
  • 人工心肺技術の教育 体外循環技術習得のための教育用シミュレータシステムによる習熟度評価の検討
    徳嶺 朝子; 二宮 伸治; 黒崎 達也; 福永 信太郎; 冨澤 康子
    人工臓器 (一社)日本人工臓器学会 36 (2) S59 - S59 0300-0818 2007/10
  • 人工心肺技術の教育 体外循環トラブル対処訓練のためのシミュレータシステムの開発と今後の展開
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 福永 信太郎; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 36 (2) S59 - S59 0300-0818 2007/10
  • 岡原 重幸; 高橋 秀暢; 二宮 伸治; 徳嶺 朝子; 池田 光輔; 黒崎 達也; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 34 (3) 235 - 235 0912-2664 2007/09
  • 岡原 重幸; 高橋 秀暢; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 34 (3) 241 - 241 0912-2664 2007/09
  • 徳嶺 朝子; 二宮 伸治; 板垣 徹; 後藤 朱里; 冨澤 康子
    体外循環技術 (一社)日本体外循環技術医学会編集委員会 34 (3) 241 - 241 0912-2664 2007/09
  • 冨澤 康子; 百瀬 直樹; 佐藤 美保子; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 大西 孝; 宍戸 圭介; 又吉 徹
    人工臓器 JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 36 (2) s57 - s61 0300-0818 2007
  • Shinji Ninomiya; Asako Tokumine; Toru Yasuda; Yasuko Tomizawa
    JOURNAL OF ARTIFICIAL ORGANS SPRINGER JAPAN KK 10 (4) 201 - 205 1434-7229 2007 [Refereed]
     
    A training system with quantitative evaluation of performance for training perfusionists is valuable for preparation for rare but critical situations. A simulator system, ECCSIM-Lite, for extracorporeal circulation (ECC) training of perfusionists was developed. This system consists of a computer system containing a simulation program of the hemodynamic conditions and the training scenario with instructions, a flow sensor unit, a reservoir with a built-in water level sensor, and an ECC circuit with a soft bag representing the human body. This system is relatively simple, easy to handle, compact, and reasonably inexpensive. Quantitative information is recorded, including the changes in arterial flow by the manipulation of a knob, the changes in venous drainage by handling a clamp, and the change in reservoir level; the time courses of the above parameters are presented graphically. To increase the realism of the training, a numerical-hydraulic circulatory model was applied. Following the instruction and explanation of the scenario in the form of audio and video captions, it is possible for a trainee to undertake self-study without an instructor or a computer operator. To validate the system, a training session was given to three beginners using a simple training scenario; it was possible to record the performance of the perfusion sessions quantitatively. In conclusion, the ECCSIM-Lite system is expected to be useful. for perfusion training, since quantitative information about the trainee's performance is recorded and it is possible to use the data for assessment and comparison.
  • 流場の物理的条件、血液の凝固条件と血栓形成の関係
    黒崎 達也; 徳嶺 朝子; 二宮 伸治; 福永 信太郎; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 35 (2) S94 - S94 0300-0818 2006/10
  • 拍動型補助人工心臓内流れ場の準定常CFD解析
    徳嶺 朝子; 二宮 伸治; 黒崎 達也; 福永 信太郎; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 35 (2) S161 - S161 0300-0818 2006/10
  • ヒューマンエラー防止のための統合型人工心肺操作訓練シミュレータの開発
    二宮 伸治; 黒崎 達也; 徳嶺 朝子; 福永 信太郎; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 35 (2) S166 - S166 0300-0818 2006/10
  • 西川 宜秀; 二宮 伸治; 濱崎 健一; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    生体医工学 (公社)日本生体医工学会 44 (2) 334 - 334 1347-443X 2006/06
  • 瀬在 明; 有岡 佐和; 時 偉; 徳嶺 朝子; 石塚 健太郎
    人工臓器 JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 35 (2) S162 - S163 0300-0818 2006
  • 流場の物理的条件と血栓形成過程の関係
    黒崎 達也; 徳嶺 朝子; 二宮 伸治; 福永 信太郎; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 34 (2) S - 110 0300-0818 2005/11
  • 瘤モデルにおけるCFD解析と血液凝固の可視化解析の比較
    徳嶺 朝子; 二宮 伸治; 黒崎 達也; 福永 信太郎; 末田 泰二郎
    人工臓器 (一社)日本人工臓器学会 34 (2) S - 111 0300-0818 2005/11
  • 太田 裕治; 近藤 修; 黒崎 達也; 徳嶺 朝子; 森田 映暁; 駒居 鑑; 高橋 祐介; 寺澤 靖雄
    人工臓器 JAPANESE SOCIETY FOR ARTIFICIAL ORGANS 34 (2) s110 - s113 0300-0818 2005

Conference Activities & Talks

  • 酸塩基平衡モデルを付加した人工心肺教育シミュレーションソフトウェアの開発  [Not invited]
    福田 雄成; 乕間 翔太; 喜納 裕; 岩下 浩幸; 高田 裕; 徳嶺 朝子
    体外循環技術  2015/09
  • タッチパネルで操作可能な人工心肺の貯血レベル制御装置の開発  [Not invited]
    百瀬 直樹; 草浦 理恵; 小久保 領; 梅田 千典; 安田 徹; 岩本 典生; 柳沢 光延; 徳嶺 朝子; 山口 敦司
    医療機器学  2015/04
  • 遠心ポンプ回転数の定量評価による貯血槽レベル自動制御システムの検証  [Not invited]
    徳嶺 朝子; 黒岡 亜貴; 柳澤 充延; 百瀬 直樹
    人工臓器  2014/09
  • 人工心肺教育シミュレーションソフトウェアの開発  [Not invited]
    徳嶺 朝子; 水野 わこ; 秋本 恵理子; 百瀬 直樹
    体外循環技術  2014/09
  • 貯血槽レベル制御システムの定量評価  [Not invited]
    徳嶺 朝子; 黒岡 亜貴; 秋本 恵理子; 柳澤 充延; 百瀬 直樹
    体外循環技術  2014/09
  • 体外循環教育シミュレータの適用による定型シナリオの手技評価と臨床経験の関係  [Not invited]
    岡西 潤; 寺本 佳弘; 二宮 伸治; 徳嶺 朝子
    日本医療教授システム学会総会プログラム・抄録集  2014/03
  • 人工心肺回路構成プログラムの開発  [Not invited]
    寺本 佳弘; 高田 裕; 秋本 恵理子; 岡西 潤; 徳嶺 朝子
    体外循環技術  2014/03
  • Momose Naoki; Tokumine Asako; Iwamoto Norio; Okada Hitomi; Kusaura Rie; Kokubo Ryo; Umeda Chinori; Yasuda Toru; Hayasaka Hideyuki; Yamaguchi Atsushi
    Japanese Journal of Extra-Corporeal Technology  2013/12 
    We designed and examined venous reservoir level automatically controlling systems for an open-fashion cardiopulmonary bypass(CPB)circuit(an open circuit level controller; OLC)and a closed-fashion CPB circuit(closed circuit level controller; CLC). The OLC system consists of a CPU(central processing unit)and a slender column inserted through the top of the venous reservoir for measuring hydrostatic pressure. The CPU analyzes the hydrostatic pressure in the column as a replacement for the venous blood level and regulates the blood pump speed in proportion to the change of the hydrostatic pressure. The CLC system consists of a commercially available level sensor, which is attached in the side wall of the venous reservoir for directly measuring the venous blood level, and a CPU regulating the blood pump speed for keeping the appropriate venous blood level.Using a mock circulation model, we confirmed the both systems could maintain an appropriate blood level in the venous reservoir and regulate blood pump speed, leading to guarantee easy and safe management of the cardiopulmonary bypass.
  • 体外循環教育システムの改良と人工心肺教育トレーニングへの応用  [Not invited]
    徳嶺 朝子; 寺本 佳弘; 山中 泰弘; 中井 紀裕; 岡西 潤; 高田 裕
    体外循環技術  2013/09
  • シミュレーション教育における操作記録の可視化とその評価  [Not invited]
    岡西 潤; 高田 裕; 寺本 佳弘; 山中 泰弘; 中井 紀裕; 徳嶺 朝子
    体外循環技術  2013/09
  • 貯血槽レベル自動制御システムOLCの動作検証  [Not invited]
    徳嶺 朝子; 百瀬 直樹; 柳澤 充延; 冨澤 康子
    人工臓器  2013/09
  • 人工臓器をめぐるシミュレーション 体外循環教育用シミュレーションシステムの現状と日本発標準型仮想患者シミュレーションモデルの提案  [Not invited]
    二宮 伸治; 戸梶 めぐみ; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    人工臓器  2013/09
  • 循環器領域の医工学 人工心肺運転訓練シミュレーション装置の開発  [Not invited]
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 末田 泰二郎
    医工学治療  2013/04
  • 体外循環教育用仮想患者シミュレーターへの自律神経制御モデル導入がメンタルワークロードに与える影響の検討  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 黒崎 達也; 徳嶺 朝子; 末田 泰二郎
    体外循環技術  2012/09
  • 米国とシンガポールにおける高再現性仮想患者シミュレーターECCSIM導入の試み  [Not invited]
    二宮 伸治; 戸梶 めぐみ; 徳嶺 朝子; 上口 晃生; 工藤 雅彰; 岡村 直哉; 黒崎 達也; 末田 泰二郎
    体外循環技術  2012/09
  • 体外循環教育における手技課題と血圧維持課題を課した技術評価の可能性  [Not invited]
    徳嶺 朝子; 岡西 潤; 寺本 佳弘
    体外循環技術  2012/09
  • 体外循環教育におけるトレーニング用シナリオ作成プログラムの開発  [Not invited]
    徳嶺 朝子; 淺山 薫; 安心院 康彦
    体外循環技術  2012/09
  • 人工心肺中のリスクマネジメント 人工心肺リスクマネジメントにおける体外循環シミュレーターの活用  [Not invited]
    徳嶺 朝子; 二宮 伸治
    体外循環技術  2012/09
  • 心臓血管外科領域の医工連携 人工心肺シミュレータの臨床への応用  [Not invited]
    黒崎 達也; 徳嶺 朝子; 二宮 伸治; 末田 泰二郎
    医工学治療  2012/03
  • 人工心肺制御システム評価における体外循環シミュレータの活用  [Not invited]
    徳嶺 朝子; 百瀬 直樹; 柳澤 充延; 二宮 伸治; 冨澤 康子
    人工臓器  2011/10
  • 体外循環技術教育用シミュレータシステムの開発と応用  [Not invited]
    徳嶺 朝子; 二宮 伸治
    臨床シミュレーション研究  2011/06
  • 体外循環教育用シミュレータECCSIMに内蔵する仮想患者モデルの構築  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    臨床シミュレーション研究  2011/06
  • 医療機器使用時のクライシスチームトレーニング 体外循環技術教育用シミュレータECCSIMのPCRM教育への適用可能性  [Not invited]
    二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 黒崎 達也
    臨床シミュレーション研究  2011/06
  • 生体工学技術による人工臓器評価 体外循環装置操作技能 チーム連携評価における仮想患者シミュレータの活用  [Not invited]
    二宮 伸治; 戸梶 めぐみ; 原 和信; 岡村 直哉; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    人工臓器  2010/11
  • 遠心ポンプ流量特性の粘度依存性と心負荷モニタリングの可能性に関する検討  [Not invited]
    岡村 直哉; 二宮 伸治; 細木 和憲; 上口 晃生; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術  2010/09
  • 教育用シミュレーターにおける送血方式選択のためのユニバーサル回路の検討  [Not invited]
    細木 政載; 二宮 伸治; 山本 卓也; 岡村 直哉; 戸梶 めぐみ; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術  2010/09
  • 脳循環モデルを付加した体外循環教育用シミュレーションシステムの検討  [Not invited]
    徳嶺 朝子; 二宮 伸治; 原 和信; 岡村 直哉; 戸梶 めぐみ; 黒崎 達也
    体外循環技術  2010/09
  • 体外循環教育用高再現性仮想患者シミュレーターのための心機能制御モデルの検討  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 岡原 重幸; 高橋 暢; 末田 泰二郎
    体外循環技術  2010/09
  • 人工心肺操作の教育・指導法 体外循環技術教育における仮想患者シミュレーター導入の効果と展望  [Not invited]
    二宮 伸治; 戸梶 めぐみ; 原 和信; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術  2010/09
  • 体外循環領域で近未来に期待される治療 心・血管制御機能を導入した仮想患者モデルによる高再現性体外循環シミュレータの可能性  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 黒崎 達也; 徳嶺 朝子; 岡原 重幸; 高橋 秀暢; 末田 泰二郎
    医工学治療  2010/04
  • 体外循環領域で近未来に期待される治療 体外循環トレーニングのための仮想患者シミュレーションシステムの開発と効果  [Not invited]
    二宮 伸治; 戸梶 めぐみ; 原 和信; 黒崎 達也; 徳嶺 朝子; 岡原 重幸; 高橋 秀暢; 末田 泰二郎
    医工学治療  2010/04
  • 心血管制御モデルを導入した体外循環シミュレータの有用性について  [Not invited]
    二宮 伸治; 戸梶 めぐみ; 黒崎 達也; 徳嶺 朝子; 原 和信
    人工臓器  2009/10
  • 教育用透析技術シミュレータシステムの構築と危機管理トレーニングへの応用  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    人工臓器  2009/10
  • 人工臓器で発生する血栓の監視と対策 人工肺前後圧および流量測定による血液粘度モニタリング法の検討  [Not invited]
    徳嶺 朝子; 二宮 伸治; 岡村 直哉; 大槻 真之; 岡原 重幸; 黒崎 達也
    人工臓器  2009/10
  • 人工臓器で発生する血栓の監視と対策 人工臓器モデル内における血栓形成 血栓形成は予測できるのか?  [Not invited]
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 末田 泰二郎
    人工臓器  2009/10
  • 圧および流量の測定による人工肺閉塞モニタリングの可能性  [Not invited]
    岡原 重幸; 高橋 秀暢; 宮本 聡史; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術  2009/09
  • 人工肺の流体力学的特性に関する基礎的検討  [Not invited]
    岡村 直哉; 徳嶺 朝子; 大槻 真之; 二宮 伸治; 岡原 重幸; 黒崎 達也
    体外循環技術  2009/09
  • 患者血行動態の維持を課題としたシミュレーショントレーニングの有効性について  [Not invited]
    二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 黒崎 達也
    体外循環技術  2009/09
  • 体外循環シミュレータ用仮想患者モデルに対する血管・心拍数制御の導入と検討  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    体外循環技術  2009/09
  • 体外循環技術の定量評価はできるか? 臨床経験とシミュレータ課題達成度の関係について  [Not invited]
    徳嶺 朝子; 二宮 伸治; 冨澤 康子
    生体医工学  2009/06
  • 医療安全における臨床工学の役割 医療安全確保のための体外循環技術教育用シミュレータの開発と有用性  [Not invited]
    二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 黒崎 達也
    生体医工学  2009/06
  • 人工臓器モデル内における血栓形成と微少圧変化  [Not invited]
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 末田 泰二郎
    人工臓器  2008/11
  • 拍動型人工心臓におけるポンプ内部の突起による内部流場の整流効果(CFD法とPIV法の比較)  [Not invited]
    佐藤 克敏; 黒崎 達也; 渡橋 和政; 末田 泰二郎; 徳嶺 朝子; 二宮 伸治; 香口 真作
    人工臓器  2008/11
  • 体外循環教育用シミュレータの動的応答の改善とその効果  [Not invited]
    徳嶺 朝子; 越川 翠; 二宮 伸治
    人工臓器  2008/11
  • 体外循環教育用シミュレータの施設教育への導入と訓練効果の検討  [Not invited]
    二宮 伸治; 黒崎 達也; 戸梶 めぐみ; 岡原 重幸; 高橋 秀暢; 徳嶺 朝子; 原 和信
    人工臓器  2008/11
  • 人工透析技術トレーニングシミュレータのための仮想患者モデルの検討  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    人工臓器  2008/11
  • 人工心肺における血液流量に連動した酸素流量調節の実験的検討  [Not invited]
    岡原 重幸; 高橋 秀暢; 宮本 聡史; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    人工臓器  2008/11
  • 患者基本情報に基づく体外循環シミュレータの血行動態パラメータ変更方法の検討  [Not invited]
    戸梶 めぐみ; 二宮 伸治; 徳嶺 朝子; 黒崎 達也
    体外循環技術  2008/09
  • 実演講演 新しい体外循環システム 体外循環技術教育用シミュレータシステムECCSIM-OriginalおよびECCSIM-Lite  [Not invited]
    二宮 伸治; 徳嶺 朝子; 戸梶 めぐみ; 西村 洵; 赤柴 徹真; 越川 翠; 黒崎 達也
    体外循環技術  2008/09
  • 人工心肺技術の教育 体外循環技術習得のための教育用シミュレータシステムの開発  [Not invited]
    二宮 伸治; 徳嶺 朝子; 黒崎 達也; 福永 信太郎; 冨澤 康子
    人工臓器  2007/10
  • 人工心肺技術の教育 体外循環トラブル対処訓練のためのシミュレータシステムの開発と今後の展開  [Not invited]
    黒崎 達也; 二宮 伸治; 徳嶺 朝子; 福永 信太郎; 末田 泰二郎
    人工臓器  2007/10
  • 人工心肺技術の教育 体外循環技術習得のための教育用シミュレータシステムによる習熟度評価の検討  [Not invited]
    徳嶺 朝子; 二宮 伸治; 黒崎 達也; 福永 信太郎; 冨澤 康子
    人工臓器  2007/10
  • 人工心肺技術の教育 体外循環訓練シミュレータECCSIM-Liteのシナリオ作成と使用経験  [Not invited]
    佐藤 美保子; 新 秀直; 久保 仁; 玉井 久義; 二宮 伸治; 徳嶺 朝子; 又吉 徹; 百瀬 直樹; 冨澤 康子
    人工臓器  2007/10
  • 体外循環訓練シミュレーターの教育セミナーでの使用経験 ECCSIM-Lite  [Not invited]
    徳嶺 朝子; 二宮 伸治; 板垣 徹; 後藤 朱里; 冨澤 康子
    体外循環技術  2007/09
  • シミュレーターを用いた人工心肺システム変更の評価について  [Not invited]
    岡原 重幸; 高橋 秀暢; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    体外循環技術  2007/09
  • 酸素流量調節における自動制御化の実験的検討  [Not invited]
    岡原 重幸; 高橋 秀暢; 二宮 伸治; 徳嶺 朝子; 池田 光輔; 黒崎 達也; 末田 泰二郎
    体外循環技術  2007/09
  • 冨澤 康子; 百瀬 直樹; 佐藤 美保子; 二宮 伸治; 徳嶺 朝子; 黒崎 達也; 大西 孝; 宍戸 圭介; 又吉 徹
    人工臓器  2007
  • ヒューマンエラー防止のための統合型人工心肺操作訓練シミュレータの開発  [Not invited]
    二宮 伸治; 黒崎 達也; 徳嶺 朝子; 福永 信太郎; 末田 泰二郎
    人工臓器  2006/10
  • 拍動型補助人工心臓内流れ場の準定常CFD解析  [Not invited]
    徳嶺 朝子; 二宮 伸治; 黒崎 達也; 福永 信太郎; 末田 泰二郎
    人工臓器  2006/10
  • 流場の物理的条件、血液の凝固条件と血栓形成の関係  [Not invited]
    黒崎 達也; 徳嶺 朝子; 二宮 伸治; 福永 信太郎; 末田 泰二郎
    人工臓器  2006/10
  • 西川 宜秀; 二宮 伸治; 濱崎 健一; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    生体医工学 : 日本エム・イー学会誌  2006/06
  • 血栓形成過程の可視化による気泡除去チャンバの抗血栓性改善  [Not invited]
    西川 宜秀; 二宮 伸治; 濱崎 健一; 徳嶺 朝子; 黒崎 達也; 末田 泰二郎
    生体医工学  2006/06
  • 人工心臓・その他  [Not invited]
    瀬在 明; 有岡 佐和; 時 偉; 徳嶺 朝子; 石塚 健太郎
    人工臓器  2006
  • 瘤モデルにおけるCFD解析と血液凝固の可視化解析の比較  [Not invited]
    徳嶺 朝子; 二宮 伸治; 黒崎 達也; 福永 信太郎; 末田 泰二郎
    人工臓器  2005/11
  • 流場の物理的条件と血栓形成過程の関係  [Not invited]
    黒崎 達也; 徳嶺 朝子; 二宮 伸治; 福永 信太郎; 末田 泰二郎
    人工臓器  2005/11
  • 太田 裕治; 近藤 修; 黒崎 達也; 徳嶺 朝子; 森田 映暁; 駒居 鑑; 高橋 祐介; 寺澤 靖雄
    人工臓器  2005

MISC

Industrial Property Rights

Awards & Honors

  • 2010/11 一般社団法人日本人工臓器学会 日本人工臓器学会技術賞
     
    受賞者: 二宮伸治;黒崎達也;末田泰二郎;戸梶めぐみ;徳嶺朝子;冨澤康子

Research Grants & Projects

  • 日本学術振興会:科学研究費助成事業 基盤研究(C)
    Date (from‐to) : 2020/04 -2023/03 
    Author : 徳嶺 朝子
     
    本課題は、開心術における人工心肺操作の与える影響を把握するための後ろ向き研究である。近年、人工心肺操作の現手技手法に伴う酸素需給バランスの関係および不適正灌流を把握する観察研究が諸外国で多く報告されている。心臓を一時的に停止させる開心術では、人工心肺操作が患者の予後に与える影響は大きく、適正灌流が保たれなければ臓器不全を起こす危険がある。特に人工心肺適用後の急性腎不全(以下、AKI)の発症率は通常の手術と比べて多いとされている。本課題では、人工心肺システムを適用した患者の術中の操作記録、および術後の生体情報の相互関連を解析することを目的とし、研究の最終的なゴールは人工心肺操作のための操作支援ソフトウェアの開発を目指している。 初年度は患者データの取得を実施した。共同研究機関にてオプトアウトを実施し同意が得られたデータのみを扱う。現在の取得症例数は約100例である。次年度さらに症例数を増やし検証を行う予定である。本研究課題では、酸素需給バランスと不適正還流を把握する。術式、手術総時間、輸血の有無、ICU滞在時間など因子ごとに統計解析を実施し、人工心肺システムを使用した心臓手術後の合併症であるAKIの危険因子等を検証した。ICU滞在時間がAKI群において有意に延長したことから、AKIは開心術後における患者の短期予後を悪化させることが示唆された。ICUにおける長期滞在は多くの医療資源が必要となるため医療費の増大にも繋がる。AKI発症を軽減することはこれらの問題の改善にもつながるため今後も症例数を増やし検討を重ねる必要がある。
  • Japan Society for the Promotion of Science:Grants-in-Aid for Scientific Research
    Date (from‐to) : 2019/04 -2022/03 
    Author : Ninomiya Shinji
     
    In order to build an integrated educational environment in cooperation with various medical simulators, we aim to develop a system in which numerical models that reproduce the circulation, respiration, metabolism, and neural control states of virtual patients, organs, and surface modules are organically linked. I did.Therefore, we have developed a simple cardiac function control algorithm that reproduces hemodynamics, a surface and sensory organ module for puncture simulation, and a module that reproduces airway shape and spacing for airway management and catheter manipulation simulation. .. In addition, we have developed a virtual medical device module and a circulatory organ module for ventilator and ECMO operation training. We have established the underlying elemental technologies for organically linked simulation modules used in critical resource management training in operating rooms and long-term care facilities.
  • Japan Society for the Promotion of Science:Grants-in-Aid for Scientific Research Grant-in-Aid for Young Scientists (B)
    Date (from‐to) : 2017/04 -2019/03 
    Author : Tokumine Asako
     
    In open-heart surgery, the heart-lung machine manipulation is an important operation that is directly linked to life. In this study, the development of a semi-automatic circulation system was performed that for arterial flow and venous return volume according to simulated blood pressure, blood delivery, reservoir level, and withdraw pressure was controlled. According to the low withdraw pressure, the arterial flow to be delivered to a defined flow rate for maintaining the (virtual) blood pressure was confirmed. In addition, we have introduced an automatic control mechanism for stopping the blood transfer pump due to a drop in the reservoir level and blood venous pressure and stopping the blood transfer pump due to an increase in blood pressure, as a safety mechanism against extracorporeal circulation. This algorithm of this semi-automatic circulation control system is capable of flow control for safe operation.
  • Ministry of Education, Culture, Sports, Science and Technology:Grants-in-Aid for Scientific Research(若手研究(B))
    Date (from‐to) : 2012 -2013 
    Author : Asako TOKUMINE
     
    Perfusionists must be well trained in standard and emergency procedures because incidents during extracorporeal circulation sometimes result in a fatality. We developed a simulator for use in perfusion education that helps perfusionists gains expert skills, thereby improving their performance. In conjunction with a controlled patient simulator, the perfusionist student can learn to maintain to vital parameters of a patient. This study suggests that a well-designed training for a patient simulator allows clinical engineering students to acquire optimal skills, enabling them to address any problems that might occur during extracorporeal circulation. Therefore, next stage is necessary to establish a scoring system that systematically relates performance in simulated scenarios to clinical competency. In this system, use of these 3 training scenarios within a perfusion education system also has the advantage of providing an index of trainees current proficiency and improvement.

Other link

researchmap



Copyright © MEDIA FUSION Co.,Ltd. All rights reserved.