KINDAI UNIVERSITY


*A space between the first name and last name, please enter

JUN Cui

Profile

FacultyDepartment of Architecture / Graduate School of System Enginnering
PositionProfessor
Degree
Commentator Guidehttps://www.kindai.ac.jp/meikan/1129-sai-gun.html
URL
Mail
Last Updated :2020/04/03

Research Activities

Research Areas

  • Social infrastructure (civil Engineering, architecture, disaster prevention), Construction environment and equipment

Published Papers

  • EXPERIMENTAL VERIFICATION OF 24-HOURS CENTRAL AIR-CONDITIONING SYSTEM OF A DETACHED HOUSE IN WARM REGION BASED ON LONG-TERM MEASUREMENT, CUI Jun, ICHIKAWA Takanori, 22(51), 631 - 636, Jun. 2016 , Refereed
  • Study on Thermal Environment of the Room using a Wall Panel Cooling and Heating System Part 7, On Input Energy for Heating, Jun. 2012
  • A STUDY ON AIR-CONDITIONING LOAD CALCULATION METHOD CONSIDERING THERMAL SENSATION OF THE RESIDENT -The influence of building insulation specifications, resident location and air conditioning system on the air conditioning load-, (675), 339 - 348, May 2012
  • Study on Vertical Temperature Distribution of Wall Radiation Heating and Air Conditioner Heating when Same PMV is Maintained, (45), 41 - 47, Dec. 2011
  • A STUDY ON AIR-CONDITIONING LOAD CALCULATION METHOD CONSIDERING THERMAL SENSATION OF THE RESIDENT -Influence of the demanded indoor thermal sensation to air-conditioning load-, 76(668), 903 - 910, Oct. 2011
  • Effects on energy conservation by inverter controls of heat soursc equipment in building air-conditioning system operations, (3), 123 - 132, Jan. 2003

Conference Activities & Talks

  • Study on optimal operation of building air-conditioning system Part 3 Energy conservation effect of heat source equipment controlled by inverter,   2003 09
  • Study on optimal operation of building air-conditioning system Part 10 Calculation of the total energy by HVAC simulation,   2003 09
  • Study on optimal operation of building air-conditioning system Part 9 Measurement survey on air-conditioning system with optimal operation with heat source equipment controlled by inverters,   2003 09
  • Study on optimal operation of building air-conditioning system Part 8 Characteristic experiment on property of heat source equipment, pump and fan controlled by inverters,   2003 09
  • Energy performance analysis of an air-conditioning system with heat pump chillers controlled by inverters,   2003 07
  • Energy conservation effect by inverter control of heat source equipment under operation of building air.conditioning system Part 9 Calculation of the total energy by HVAC simulation,   2003 03
  • Energy conservation effect by inverter control of heat source equipment under operation of building air.conditioning system Part 8 Measurement survey on air-conditioning system with optimal operation with heat source equipment by inverters,   2003 03
  • Energy conservation effect by inverter control of heat source equipment under operation of building air-conditioning system Part 7 Characteristic experiment on property of heat source equipment, pump and fan controlled by inverters,   2003 03
  • An indoor temperature and humidity calculation method of multiple.floor office building using the successive state transition method,   2003 03